C&K Securitech

9

CIRCUIT PROGRAMMING MATRIX REFERENCE GUIDE

LED 1

LED 2

LED 3

LED 4

LED 5

LED 6
TAMPER LED

ALARM

ISOLATE IN
HOME SET

ISOLATE IN
NIGHT SET

WALK THROUGH
ENTRY ROUTE

CHIME

ISOLATE
PERMIT

FULL SET
ENTRY ZONE

NIGHT SET
ENTRY ZONE

WALK THROUGH
ENTRY ROUTE

CHIME

ISOLATE
PERMIT

24 HOUR ZONE

BELLS &
STROBE

WARNING
TONE

FIRE

BELLS &
STROBE

P.A.

VIEW FROM LEFT TO RIGHT. USE KEY 1 TO 6 TO SWITCH LED ON OR OFF.

ZONE TYPES ARE SHOWN IN BOLD TYPE. COLUMNS TO THE RIGHT OF THE
ZONE TYPE SHOW APPLICABLE OPTIONS. MORE THAN ONE PER ZONE TYPE
MAY BE SELECTED. SELECT A PRIMARY OPTION (BOLD TEXT) THEN SELECT
ANY SECONDARY OPTION BY GOING TO THE RIGHT FROM THE ONE YOU
CHOOSE. IN ROW 2, FULL SET ENTRY AND NIGHT SET ENTRY MAY BOTH BE
APPLIED TO THE SAME ZONE. LED NUMBERS AT THE TOP OF THE CHART DO

NOT

 REFER TO THE ZONE NUMBER.

ZONE ATTRIBUTES AND MEANINGS

.

ALARM. 

A standard alarm zone. This zone will signal alarm if tripped

while the control is in the fully armed condition. In the day condition visual
indication may be programmed. (option 7-4-1)

FULL SET ENTRY ZONE.

 This zone type controls the entry and exit to

and from the alarm system. When the control is armed tripping the zone
will start a timed entry period during which time the system should be
disarmed. Failure to do so will result in a full alarm condition. When
arming is requested this is the last zone to pass through before leaving
the system. It can be fully set using a timer or by seeing the last sensor
close or reset. (final contact closure). Alternatively a terminator set button,
outside the protected area can arm the system, if all zones are clear. If a
zone is programmed for both Full set and Night set entry it can be final
contact setting in the former and timed entry/exit in the latter.

NIGHT SET ENTRY ZONE. 

This zone type has the same attributes as the

Full set entry zone except that it is associated with one of the night set
conditions. Night Set or Home Set. Even when the system is only partly
armed we still need some method of entering and leaving it. Although a
single zone may be programmed for both types of operation it may also
be 2 different ones.

Summary of Contents for ACTIVE 5

Page 1: ...ACTIVE 5 ENGINEERING MANUAL C K Systems Ltd C031 066 Issue 3...

Page 2: ...the alarm system Up to 3 remote keypads can be used on the system The positioning of these should be agreed with the user once the entry exit routes and the Part Set functions have been explained to t...

Page 3: ...however if for some reason you find it not to be the same simply perform a factory reset and this will revert the panel to the above settings SPECIFICATION FOR SOFTWARE REVISION NUMBER V3 0 The softwa...

Page 4: ...cable must be separate to all other wiring The cable MUST be earthed and we recommend power is taken from a 3 Amp fused spur and wired by a qualified electrician 2 Battery connection The Active 5 req...

Page 5: ...m the AUX 12 6 Internal sounders Speaker The control panel is fitted with a 35 Ohm speaker in the housing to aid in audible alarms If an extra speaker s is required it should be connected to the termi...

Page 6: ...be fitted mark the holes for the mounting position 2 Screw the backbox in the agreed position 3 Note the rear entry of cabling WIRING A REMOTE KEYPAD 1 The remote keypads require 6 core cable for the...

Page 7: ...ur contact or shunt lock needs to go between S2 and the right hand terminal of the exit zone LINE FAULT INPUT If you are using the Active 5X which is a comms version of the Active 5 control panel you...

Page 8: ...nds whereby the panel will jump out of engineering mode automatically Pressing the HASH key will manually exit engineering If for any reason you need to return to engineering mode you can enter your e...

Page 9: ...4 will light up This has been preset for factory default at 15 minutes A new time may be programmed by entering the keys which when totalled up come to the desired time Once program is set Press to c...

Page 10: ...ion In the day condition visual indication may be programmed option 7 4 1 FULL SET ENTRY ZONE This zone type controls the entry and exit to and from the alarm system When the control is armed tripping...

Page 11: ...be selected with alarm type zones This will make the zone in operative during the Night set arming period Night set arming cannot be selected until one zone has had this option selected WALK THROUGH...

Page 12: ...und Follow this procedure for all or any zones you want to program NOTE All entry zones are isolated in home set Full set entry acts as normal alarm in night set Night set entry acts as normal alarm i...

Page 13: ...system may only be reset by the installer or his representative Entry of the Engineer code is required befo re the system will set again 72 2 Eng only PA reset Following a PA alarm which has been rem...

Page 14: ...R H H RTN ACTIVEGUARD STB S 12V 12V RIGHT HAND TAMPER ACTIVE GUARD 3 ST SW V V RET SECURIGUARD STROBE S SUPPLY SUPPLY LEFT HAND TAMPER NOVA GUARD 2 T STROBE S 12V 12V R SPIRIT AU1000 STB TRG HOLD OFF...

Page 15: ...ROPEAN OPTIONS BATTERY VOLTAGE V AUX VOLTAGE V INSTALLED BY THIS INFORMATION SHOULD BE KEPT EITHER INSIDE THE CONTROL PANEL OR WITH THE INSTALLER IT CAN BE USED TO REFER TO PROGRAMMING DETAILS WHEN NE...

Reviews: