ERROR 0X8010 - Can't Stow (EL Limit)
Cause:
This error will occur if the Elevation Stow switch fails to come on during the last stow attempt.
The controller will no longer allow the user to stow the antenna automatically until the switch is fixed.
Solution:
a.
Using the manual controls on the front of controller, move the platform to the stow position
on 2 axes. Move the AZ=0.0, then begin to lower the antenna until stowed.
755/985 stow position
b.
Once the controller confirms The EL ST switch is activated, a message indicating “EL Limit
Fixed” will appear and the user can proceed stowing the platform automatically.
If the Elevation ST does not come on in the Stowed position then the switch will need to be tested.
Proceed to Step 1