Rev F
Maintenance
6-1
C H A P T E R 6
Maintenance
This chapter discusses the installation and/or replacement of fuses, power supplies, RF modules, and
housings.
Fuse/Brass Shorting Bar (Slug) Replacement
H. E. Power Supply Replacement
General Inspection
Inspect the entire unit for the following each time maintenance and adjustments are done:
■
damaged or missing gaskets (rubber in the base or metal mesh in the lid)
■
loose modules or assemblies
■
missing, open (blown), loose or misaligned fuses
■
heat damage (burn marks, charred components)
■
water damage
Fuse/Brass Shorting Bar (Slug) Replacement
WARNING
: Hazardous voltages are present. Use approved safety equipment and
procedures. Do not energize any station until all other stations in the power supply group
have been installed.
CAUTION
: Improper fuse installation can:
■
damage the amplifier
■
fail to power the amplifier
■
fail to distribute through power
CAUTION
: Damaged fuseclips or misaligned fuses can cause heat damage. Do not force
or misalign the fuse when installing.
Summary of Contents for FlexNet E7
Page 2: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM...
Page 16: ...1 8 FlexNet 700 Series Line Extender Rev F 1...
Page 26: ...2 10 FlexNet 700 Series Line Extender Rev F 2...
Page 64: ...4 22 FlexNet 700 Series Line Extender Rev F 4...
Page 82: ...A 6 FlexNet 700 Series Line Extender Rev F A...
Page 88: ...B 6 FlexNet 700 Series Line Extender Rev F B...
Page 102: ...C 14 FlexNet 700 Series Line Extender Rev F C...
Page 104: ...D 2 FlexNet 700 Series Line Extender Rev F D...
Page 110: ...Index 4 Rev F...
Page 111: ...Introduction fm Page 10 Monday April 1 2002 12 43 PM...