PN 060914-000
Revision C, October 2001
Page 2-13
© 2001, C-COR.net Corporation
8. Measure and cut three lengths of 18 AWG wire for each terminal block to be connected.
Strip the insulation from the last 1/2 inch on both ends of the wire and crimp a fork/
spade crimp terminal to each end. Connect as follows:
a. Connect one wire from the Fan/Power Supplys
V screw-terminal to the HWX
Equipment Shelfs
screw-terminal, tighten screw terminal securely.
b. Connect the second wire from the Fan/Power Supplys +V screw-terminal to the
HWX Equipment Shelfs
+
screw-terminal, tighten screw terminal securely.
c. Connect the third wire from the Fan/Power Supplys GND screw terminal to the
HWX Equipment Shelfs GND screw-terminal, tighten screw terminal securely.
Warning:
Do not yet attach the Fan/Power Supply AC power cord.
Stop! You have completed this procedure.