background image

BOOM

 

INSTALLATION

 

 

Quick

 

Smart

 

Mounted

 

​​

Booms

 

Only

 

 

For

 

booms

 

without

 

Quicksmart™,

 

bolt

 

the

 

boom

 

to

 

an

 

appropriate

 

surface

 

using

 

the

 

boom

 

mounting

 

holes. 

 
With

 

QSA

 

Frame; 

Fit

 

QS

 

upright

 

bars

 

to

 

centre

 

frame

 

of

 

sprayer

 

using

 

M10x30

 

bolts

 

and

 

nuts

 

supplied.

 

Fit

 

with

 

mounting

 

lugs

 

facing 

inwards. 
Fit

 

sprayer

 

to

 

Quicksmart™

 

frame

 

and

 

unfold

 

arms. 

 

With

 

QS

 

Frame; 

Install

 

the

 

Quicksmart™

 

frame

 

as

 

detailed

 

in

 

the

 

mounting

 

instructions.  

Fit

 

sprayer

 

to

 

Quicksmart™

 

frame

 

and

 

unfold

 

arms. 

Set

 

boom

 

to

 

required

 

spraying

 

height

 

by

 

fitting

 

the

 

QS

 

mount

 

bars

 

on

 

the

 

high

 

or

 

low

 

position,

 

and/or

 

adjusting

 

the 

position

 

of

 

the

 

mount

 

bars

 

on

 

the

 

centre

 

frame

 

of

 

the

 

sprayer. 

 

NOTE

 

The

 

QS

 

upright

 

bars

 

can

 

be

 

adjusted

 

in

 

50mm

 

increments

 

on

 

the

 

sprayer

 

centre

 

frame. 

 
 

Boom

 

Height 

 
Minimum

 

recommended

 

boom

 

height

 

above

 

the

 

​​

target

​​

 

is

 

50cm

 

for

 

110

0

 

nozzles

 

(standard)

 

and

 

60cm

 

for

 

80

0

 

nozzles 

(optional). 
Test

 

the

 

evenness

 

of

 

distribution

 

by

 

spraying

 

an

 

area

 

of

 

dry

 

concrete

 

with

 

clean

 

water.

 

​​

 

The

 

surface

 

must

 

dry

 

evenly. 

If

 

the

 

target

 

is

 

above

 

ground

 

level,

 

raise

 

the

 

boom

 

height

 

accordingly.  

 
 

Plumbing

 

(12V

 

Pump)

 

 
Cut

 

the

 

sprayer

 

output

 

line

 

from

 

the

 

pump

 

in

 

an

 

easily

 

accessible

 

position,

 

and

 

install

 

the

 

quick

 

release

 

valve

 

with

 

the 

8.5mm

 

hose

 

shank. 

Connect

 

the

 

delivery

 

hose

 

to

 

the

 

boom,

 

cut

 

the

 

hose

 

to

 

a

 

length

 

so

 

that

 

it

 

can

 

be

 

connected

 

to

 

the

 

quick

 

release

 

valve 

using

 

the

 

10mm

 

male

 

hose

 

shank

 

connector.   

Connect

 

the

 

remainder

 

of

 

the

 

sprayer

 

output

 

line

 

to

 

the

 

spray

 

gun,

 

to

 

the

 

remaining

 

8.5mm

 

male

 

hose

 

shank 

connector. 
 
 

Plumbing

 

(PTO

 

or

 

Engine

 

Driven

 

Pump)

 

 
Single

 

Section

 

Spraying: 

Connect

 

the

 

boom

 

delivery

 

line

 

to

 

a

 

spare

 

outlet

 

port

 

on

 

the

 

sprayer

 

pressure

 

regulator,

 

secure

 

with

 

hose

 

clamps 

provided. 
 
Multi

 

Section

 

Spraying: 

Connect

 

each

 

spraying

 

section

 

boom

 

delivery

 

line

 

to

 

a

 

spare

 

outlet

 

port

 

on

 

the

 

sprayer

 

pressure

 

regulator,

 

secure

 

with 

hose

 

clamps

 

provided.

 

Extra

 

regulator

 

outlet

 

ports

 

are

 

available

 

(depending

 

on

 

specification). 

 
 

THEORY

 

OF

 

OPERATION 

 
Spray

 

fluid

 

is

 

placed

 

in

 

the

 

tank

 

where

 

it

 

is

 

drawn

 

through

 

a

 

suction

 

filter

 

and

 

pumped

 

to

 

a

 

control

 

valve.

 

​​

 

The

 

excess 

flow

 

from

 

the

 

valve

 

is

 

returned

 

to

 

the

 

tank

 

via

 

the

 

bypass

 

hose.

 

​​

 

Fluid

 

at

 

a

 

nominal

 

pressure

 

of

 

1-4

 

bar

 

(nominally)

 

is 

pumped

 

to

 

the

 

spray

 

tips

 

via

 

nozzle

 

tip

 

strainers. 

At

 

the

 

spray

 

tip,

 

fluid

 

is

 

atomized

 

at

 

the

 

spraying

 

pressure

 

and

 

the

 

fluid

 

is

 

propelled

 

toward

 

the

 

target

 

at

 

the

 

tip

 

angle 

(80°

 

or

 

110°

 

nominally). 

 

Y:\Manuals\Current\90024-3-PNozz.DOC

 

​​

 

​​

 

​​

 

Summary of Contents for Pressure Nozzle Boom Kit

Page 1: ...OWNER S MANUAL FOR THE PRESSURE NOZZLE BOOM KIT C Dax Systems Ltd P O Box 1010 145 Harts Road Tiritea Palmerston North Ph 64 6 354 6060 Fax 64 6 355 3199 E Mail sales c dax co nz www c dax com...

Page 2: ...Y Manuals Current 90024 3 PNozz DOC 2...

Page 3: ...trained in safety This also applies to equipment that is loaned or rented to someone who has not read the owner s manual and is not familiar with the operation of application equipment NEVER EXCEED TH...

Page 4: ...r a hat long sleeved cotton overalls and boots If you use pesticides regularly it is a good idea to always wear a respirator to avoid cumulative effect Other protection may be required Check the label...

Page 5: ...nted Booms Only Boom Height Plumbing 12V Pump Plumbing PTO or Engine Driven Theory of Operation 6 Operation Calibrating your Pressure Nozzle Boom 7 Calibration Chart Select Tip Size 8 Spray Tip Select...

Page 6: ...ced or dismantled by any person other than a service agent or person authorised by C DAX Systems The warranty does not extend to cover consequential damage repair or replacement of parts due to fair w...

Page 7: ...t line from the pump in an easily accessible position and install the quick release valve with the 8 5mm hose shank Connect the delivery hose to the boom cut the hose to a length so that it can be con...

Page 8: ...ed you may need to repeat the spraying which will be wasting your money and time Chemicals are expensive Repeat calibration frequently during the seasons to avoid disappointment To calibrate your spra...

Page 9: ...g calibration table CALIBRATION CHART NOTES chemical field etc STEP 1 Applicatio n Rate of Chemical litres or kilo per hectare STEP 2 Tank Volume litres STEP 3 Forward Speed KPH STEP 4 Average Nozzle...

Page 10: ...ax systems endeavours to match the boom output flow to the 12V pump size so there is no need to change the tip size All spray tips supplied by C Dax Systems conform to an international standard for ti...

Page 11: ...0 UF 02 1 5 0 56 112 84 67 56 48 Yellow 2 0 0 65 130 98 78 65 56 2 5 0 73 146 110 88 73 63 3 0 0 80 160 120 96 80 69 3 5 0 86 172 129 103 86 74 4 0 0 92 184 138 110 92 79 1 0 0 69 138 104 83 69 59 110...

Page 12: ...ly Check the spray tip patterns for wear replace if necessary Calibrate the boom every 100Ha Lubricate any moving boom parts Check spray hoses for kinks or damage replace if necessary Annually Replace...

Page 13: ...2 0 76 0 71 1 10 1 02 0 95 0 88 1 35 1 25 1 15 1 08 1 1 1 1 V400 4A 8002 pump 4 20 110UF02 0 53 80 64 50 0 62 0 78 1 0 1 0 1 25 1 6 1 V400 4A 8003 pump 4 70 110UF02 0 59 90 71 59 0 55 0 70 0 85 0 88 1...

Page 14: ...Y Manuals Current 90024 3 PNozz DOC 14...

Page 15: ...and diaphragm 10492 3 Diaphragm only 10493 4 Fly nut 10343 5 Swivel clamp Part of 10480 6 Swivel clamp pin Part of 10480 7 O Ring 10299 9 Swivel clamp screw 10497 10 Cap and gasket No tip 10710 12 Noz...

Page 16: ...en used successfully in N Z sine 1984 and for over 10 years in the U S A Why C DAXOIL Works C DAXOIL wraps up the chemical in an emulsifiable natural vegetable oil This encapsulation is advantageous t...

Reviews: