ROUTINE MAINTENANCE
Cleaning
Clean the sprayer regularly! After each use flush the unit out three times with fresh water. Use a neutralizing
agent for the second rinse.
CAUTION
To prevent damage to the sprayer and spray gun, drain the water from the sprayer and spray gun when there is
a risk of frost.
Filters
There are four filters in each Sprayrider™ fluid system. Each one must be checked and cleaned after each use.
The tank strainer basket is retained by the lid to assist cleaning. Always clean the strainer before filling the tank
with spray solution.
The C-Dax valve assembly at the base of each leg has a stainless steel mesh filter for straining the fluid before
it reaches the pump. Unscrew the cap at the base of each leg and allow the valve assembly to hang free from
the tank. This exposes the valve filter mesh for cleaning. Take care not to lose the O-ring.
Carefully rinse each stainless steel mesh with a hose.
CAUTION
To avoid damage to the filter mesh, do not attempt to remove the mesh from the valve assembly.
Do not use excessive pressure when cleaning the valve and filter mesh.
CAUTION
When refitting the valve, do not overtighten the valve nut. Tighten to hand tight only.