Parts List and Exploded View 

 

Item  Description 

Quantity 

Stand 

Terminal Knob 

Washer 

Insulating Disc 

Insulating Sleeve 

Electrode Pressure Knob 

Back Plate 

Current Collector 

Electrode 

10 

Electrode Gasket 

11 

Reference Electrode Port Plug 

12 

Electrode Port 1/8” 

13 

Electrode Port 1/16” 

14 

Back Frame 

15 

O Ring ID 40.95 Dia 2.62 

16 

Membrane Gasket 

17 

Membrane (not supplied) 

18 

O Ring ID 50.47 Dia 2.62 

19 

Front Frame 

20 

Front Plate 

21 

Thumb Nut  

22 

Membrane Template 

23 

Membrane Gasket Template 

24 

Electrode Gasket Template 

 

Summary of Contents for LAB 1x1

Page 1: ...21 08 2019 1 C Flow LAB 1x1 Instruction Manual...

Page 2: ...Contents 1 Introduction 3 2 Safety 4 3 Unpacking 4 4 Specifications 5 5 Assembly Instructions 6 6 Parts List and Exploded View 7 7 Troubleshooting 9 8 Cleaning 9 9 Templates 9 10 Other C Flow Product...

Page 3: ...d is shown in the on line video demonstration The unit is designed for ease of use and no tools are required for assembly The cell comes equipped with a set of electrodes but it is designed so that yo...

Page 4: ...r measure the pressure at the entrance to the cell and restrict the liquid flow rate so that the pressure does not exceed 1 bar gauge The user should check the pressure rating of any tubing or fitting...

Page 5: ...x 10 mm Electrode material carbon supplied as standard Current collectors brass Electrolyte ports PEEK Reference electrode blanks PEEK Cell Frames CPVC Gasket material EPDM Membrane material not suppl...

Page 6: ...tional Fit Membrane Gasket Membrane and second Membrane Gasket The purpose of the Membrane Gaskets is to locate a Membrane if used Fit O Ring into face of Front Frame and fit the Front Frame over the...

Page 7: ...Current Collector 2 9 Electrode 2 10 Electrode Gasket 2 11 Reference Electrode Port Plug 2 12 Electrode Port 1 8 4 13 Electrode Port 1 16 2 14 Back Frame 1 15 O Ring ID 40 95 Dia 2 62 1 16 Membrane G...

Page 8: ...21 08 2019 8...

Page 9: ...ow Rate Check piping not kinked Poor Electrical Contact Check Current Collector face is clean and bright Use solvent and or gentle abrasive Check rear side of electrode is clean Use solvent and gentle...

Page 10: ...cess development in industry or academia A wide variety of electrochemical processes can be carried out on C Flow PLT including the treatment of dilute systems e g waste water chemical synthesis visco...

Page 11: ...h Innovation Ltd does not accept liability for any direct or consequential loss arising from use of this manual or its contents and gives no warranty or representation express or implied as to the fit...

Page 12: ...21 08 2019 12 C Tech Innovation Ltd Capenhurst Technology Park Capenhurst Chester UK CH1 6EH Tel 44 0 151 347 2900 info ctechinnovation com www ctechinnovation com...