Direct
LOGIC PLCs Password Protection
NOTE: Direct
LOGIC PLCs support multi-level password protection of the ladder program. This allows
password protection while not locking the communication port to an operator interface. The multilevel
password can be invoked by creating a password with an upper case "A" followed by any variation of seven
numeric characters (e.g. A1234567). Please refer to the specific PLC user manual for further details.
PLC Compatibility and Connection Charts
The following pages include charts that list the recommended cables and/or manufactured
devices that can be used to make up the communications link between several brands of PLC’s
and the
C-more
6” Micro-Graphic panel. Port2 is a 15-pin D-sub communication port that
supports RS-232, RS-485 and RS-422. An external 1 Amp @ 12-24 VDC external power
source is required.
Note:
Recommended DC power supply to power the
C-more
Micro-Graphic Panel,
AutomationDirect
Part
No. PSP24-024S or PSP24-024C.
The chart also refers to wiring diagrams that can be used to construct cables for connecting the
PLC’s port to the panel’s port. The constructed cables are referred to as Diagram 1 through 13
and start on page 6-26.
Following the charts is a list of cables that can be purchased, including their wiring diagrams,
and also wiring diagrams that are referenced from the charts that can be used to construct the
referenced cables.
6–5
Chapter 6: PLC Communications
EA1-TCL-M Hardware User Manual, 1st Ed., 12/09
®
6