SERIAL COMMUNICATION INTERFACES
Page 36
7.3
Input Sentences
The serial interfaces of the R4 Navigation System supports receiving and
interpreting the input sentences described in Table 7-1 below. The user can
configure which messages to receive and interpret and which port to receive
them on. This is described in section “Input Config” in the Reference
chapter of the Operator’s Manual, Ref. [1].
The
PSTT,510
sentence is always interpreted if received.
Sentences can be received on the User 1 and User 3 ports.
Table 7-1. Interpreted IEC 61162-1 and proprietary input sentences
Sentence Name
ACK
Acknowledge Alarm (Note 1)
DBT
Depth below transducer
DPT Depth
HDG
Heading, deviation and variation
HDT Heading,
true
VHW
Water speed and heading
RTE Routes
Rnn
Routes (for old NMEA compliance)
WPL Waypoint
location
PSTT,510
Set RAIM accuracy level (proprietary message)
Note 1: The ACK message alarm identifier must be identical to the
identifier field in the ALR output message relating to the alarm to be
acknowledged.