2.1.3
Disarming Indication
If the key, with which you can change the partition status and this partition is armed, is read, then the partition
is disarmed.
The disarming is indicated after the reading is completed.
Disarming indication: the LED turns on for 5 seconds and turns off.
After the disarming indication is displayed, the standby mode indicator is enabled.
2.1.4
Arming Indication
If a key, with which it is possible to change the partition status, is read, then if there are no zones in the partition
with exit delay, the partition is armed. If there are zones with exit delay, then the delay interval counting starts;
arming is performed after the exit delay expires.
The arming indication depends on how many partitions are configured in the device.
One Partition
If only one partition is configured in the device, then after it has been armed, the LED turns on and remains lit:
the standby mode indicator with the only partition armed is enabled.
Several Partitions
If several partitions are configured in the device, then the indication after the current one is armed depends on
whether the disarmed partitions remained or not.
If all partitions are armed, the LED turns on and remains lit: the standby mode indicator with several partitions
is activated, all partitions are armed.
If there is at least one not armed partition, the LED turns on and is glowing for 20 seconds. After that, the
indication of the standby mode with several partitions is enabled, some of which are disarmed.
Arming Rejection
“Arming rejection” is the impossibility to arm the site, if the security alarm on the site is faulty, or arming is
prohibited due to lack of payment for security services.
There are the following reasons for arming rejection:
∙
malfunction of one or more zones;
∙
alarm in one or more zones;
∙
no communication with the panel program via IP channel;
∙
absence of 220V on the site;
∙
no payment for security services;
∙
the device case is opened.
2.1.5
Standby Mode Indication
At the time of the reading indication, arming/disarming errors, arming and disarming the indication of the standby
mode is interrupted.
The standby mode indication depends on how many partitions are configured in the device.
11