CLIMEXEL HEAT PUMPS MANUAL
pag. 8 di 18
Ver.02
–
2017-08-04
1.
IC 121 CX CONTROLLER
CONDENSATE DRAIN
START-UP
The purpose of the controller is to maintain the temperature of the pool water. Its
functions are as follows:
•
Starting / stopping the machine
•
Maintain the pool water temperature according to the temperature difference (or
•
Δ
T) between the inlet and outlet of the machine and the ambient temperature.
•
Display the inlet and outlet water temperature and the room temperature
•
Display alarms / indicate a defrosting cycle
The machine's support base must have a very
slight slope (approx. 1-2%) towards the corner
of the collection basin chosen for draining the
condensate.
Use one of the corner holes in the lower
collection basin to drain the condensation.
The basin is equipped with rubber plugs, one of
which is perforated: this must be placed at the
drainage point, as shown in the figure opposite.
If the ground is not able to absorb the generated
condensation, it will be necessary to provide for
the realisation of a drain.