USER MANUAL
- ENG -
www.cpa-piscine.it
pag. 32
Ver.00
–
AQ10MC-R32
–
2019-05-07
2. Leakage detection notice and method
a.
Leakage checking is prohibited in closed area.
b.
The ignition source is prohibited during the leakage inspection. A halide torch (or any
other detector using a naked flame) shall not be used.
c.
Leakage detection fluids can be applied with most refrigerants but the use of
detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode
the copper pipe.
d.
Vacuumize completely before welding. Welding can only be carried out by professional personnel in
service center.
e.
Please stop using while gas leakage occur, and contact professional personnel in service center.
3. Trial
a.
The user must “Start the Pump before the
Machine, and Turn off the Machine before the Pump”, or the
machine will be damaged.
b.
Before start the heat pump, please check for any leakage of water; and set suitable temperature in the
thermostat, and then switch on power supply.
c.
In order to protect the swimming pool heater, the machine is equipped with a time lag starting function, the
fan will run 1 minute earlier than the compressor when starting the machine, and it will stop running 1
minute later than the compressor when power off the machine.
d.
After the swimming pool heater start up, please kindly checking for any abnormal noise from the machine.
G. Maintenance
“
CUT OFF
”
power supply of the heater before cleaning, examination and repairing
In winter season when you don’t swim:
a. Cut off power supply to prevent any machine damage.
b. Drain water clear of the machine.
!!Important:
Unscrew the water nozzle of inlet pipe to let the water flow out.
When the water in machine freezes in winter season, the titanium heat
exchanger may be damaged.
1.
Cover the machine body when not in use
2.
Please clean this machine with household detergents or clean water, NEVER use gasoline, thinners or any
similar fuel.
3.
Check bolts, cables and connections regularly.
4.
If repair or scrap is required, pls contact authorized service center nearby.
5.
Do not attempt to work on the equipment by yourself. Improper operation may cause danger.
6.
In case of risking, safety inspection must be carried before the maintenance or repairing for heat pumps with
R32 gas.