Operator Manual
BB3002 Page 90
Initial issue: 05/08
Latest revision: 09/14
7 .2 Purging system sequence
aTTenTIon:
In case of purge of cleaner, Setpoint temperature should be adjusted to
150
°c
(see chapter
"8.4 Adjusting Temperature on PUR C Melter", page 98.
Purge System daily to remove grease and left over PUR material from previous day before
beginning production.
Remove cured glue using tool. Cured = skin on surface.
Note: In case of standby higher than 3 hours, without grease on the gun openings,
the system must be purged.
1. Press the "Tools" button
(1) then the button illustrating the PUR System (2).
2. Starting from the home page shown in the picture on the left, press the purge button (3) as shown.
The screen of the "Purge page" will appear on the right.
3. Following the instructions on the "Purge page" : Open the door and cover.
Remove excess of grease left the day before. Grease the purge cup. Place purge cup over
slot. Close slot manually with the hand wheel until guide plates are snug against the purge cup.
2
1
3