SET UP INSTRUCTIONS

1.   Remove the boom microphone socket cover (

M

) and install the Boom Microphone (

N

) by plugging into the socket (

O

) on the Interior 

Unit.  Retain the socket cover for future use.

2.   Confirm that the Communicator starts by pressing the POWER/MUTE button (

P

).  The POWER/MUTE indicator (

Q

should now be illuminated.  If the unit does not start, check the wiring and wall outlet.

3.   Verify that the Communicator works by talking into the Interior Boom Microphone (

N

) and the Exterior Microphone (

X

).  

Do not speak into the Interior Boom Microphone from closer than two inches (51 mm).  See VOLUME adjustment notes below.

CONTROLS

POWER/MUTE

- When the Communicator is off, the POWER/MUTE indicator (

Q

) will not be lit.

Pushing the POWER/MUTE button (

P

) will start the Communicator. The POWER/MUTE indicator (

Q

) will be Green when the 

Communicator is 

ON

.  

Press again to cycle between 

ON

and 

MUTE

. In the 

MUTE

mode the POWER/MUTE indicator (

Q

) will be flashing Red.  

Depressing the switch for two seconds will turn the unit 

OFF

.  The POWER/MUTE indicator (

Q

) will not be lit when the Communicator is 

OFF

.

VOLUME

– To adjust the interior and exterior speaker volume, press the 

INT

ERIOR volume rocker switch (

R

) or 

EXT

ERIOR volume

rocker switch (

S

).  Pressing the rocker switch up will increase the volume, and pressing the switch down will decrease the volume.  Try

to keep the volume as low as needed to effectively communicate.

8.   One end of the Power Cable 

(

H

)  

has the two inner wires exposed. Keep 9" - 12" (227mm -305mm) of this end on the inner unit 

      side and feed the Power Cable through its access hole toward where the unit will be plugged into a wall outlet.  Cut off an 
      appropriate amount of excess Power Cable, considering the length of the cable attached to the Transformer (

L

).  Strip the outer 

      gray insulation sheath back to expose approximately 1-1/2" (38mm) of the two inner wires. Strip back the red and black insulation 

       from the inner two wires to expose approximately 1/8" – 3/16" (3mm - 5mm) of bare wire.

9 .  Install the wires into the terminals on the back of the Interior and Exterior Units.  The back of each unit has a color-coded label to 

      indicate which wire goes into which terminal.  Firmly tighten each screw to hold the wires in the terminal.  Lightly tug on each wire 

       to make sure that it is held securely in place.

10. Secure the Mounting Plates (

E

) to the counter using the supplied Mounting Screws (

G

).  Use the supplied Screw Anchors (

J

      if appropriate for the counter material.

11. Install the Interior and Exterior Units onto the Mounting Plates.  Feed loose cable back into the access holes.  Secure the units to 

      the plates using the Security Torx Screws from Step 2.

12. Install the Power Adapter (

K

) onto the free end of the Power Cable.  Make sure that the red wire (

positive

) is inserted into the 

      terminal under the (

+

) symbol and the black wire (

negative

) is inserted under the (

-

) symbol.  Tighten the terminal screws down 

      on the wires and lightly tug on the wires to make sure they are held securely in place.

13. Plug the Transformer/Power Supply (

L

) into a normal wall outlet and insert its jack into the Power Adapter 

(

K

)

      

The Transformer can be used for both 115V and 240V outlets (range of 100V to 240V). Optional plug adapters are available 

       for Europe (EUSS412) and Australia (AUWSS416).