crlaurence.com •
Phone Toll Free
(800) 421-6144 •
Fax Toll Free
(800) 458-7496
SET UP INSTRUCTIONS
1. Remove the boom microphone socket cover (
M
) and install the Boom Microphone (
N
) by plugging into the socket (
O
) on the Interior
Unit. Retain the socket cover for future use.
2. Confirm that the Communicator starts by pressing the POWER/MUTE button (
P
). The POWER/MUTE indicator (
Q
)
should now be illuminated. If the unit does not start, check the wiring and wall outlet.
3. Verify that the Communicator works by talking into the Interior Boom Microphone (
N
) and the Exterior Microphone (
X
).
Do not speak into the Interior Boom Microphone from closer than two inches (51 mm). See VOLUME adjustment notes below.
CONTROLS
POWER/MUTE
- When the Communicator is off, the POWER/MUTE indicator (
Q
) will not be lit.
Pushing the POWER/MUTE button (
P
) will start the Communicator. The POWER/MUTE indicator (
Q
) will be Green when the
Communicator is
ON
.
Press again to cycle between
ON
and
MUTE
. In the
MUTE
mode the POWER/MUTE indicator (
Q
) will be flashing Red.
Depressing the switch for two seconds will turn the unit
OFF
. The POWER/MUTE indicator (
Q
) will not be lit when the Communicator is
OFF
.
VOLUME
– To adjust the interior and exterior speaker volume, press the
INT
ERIOR volume rocker switch (
R
) or
EXT
ERIOR volume
rocker switch (
S
). Pressing the rocker switch up will increase the volume, and pressing the switch down will decrease the volume. Try
to keep the volume as low as needed to effectively communicate.
8. One end of the Power Cable
(
H
)
has the two inner wires exposed. Keep 9" - 12" (227mm -305mm) of this end on the inner unit
side and feed the Power Cable through its access hole toward where the unit will be plugged into a wall outlet. Cut off an
appropriate amount of excess Power Cable, considering the length of the cable attached to the Transformer (
L
). Strip the outer
gray insulation sheath back to expose approximately 1-1/2" (38mm) of the two inner wires. Strip back the red and black insulation
from the inner two wires to expose approximately 1/8" – 3/16" (3mm - 5mm) of bare wire.
9 . Install the wires into the terminals on the back of the Interior and Exterior Units. The back of each unit has a color-coded label to
indicate which wire goes into which terminal. Firmly tighten each screw to hold the wires in the terminal. Lightly tug on each wire
to make sure that it is held securely in place.
10. Secure the Mounting Plates (
E
) to the counter using the supplied Mounting Screws (
G
). Use the supplied Screw Anchors (
J
)
if appropriate for the counter material.
11. Install the Interior and Exterior Units onto the Mounting Plates. Feed loose cable back into the access holes. Secure the units to
the plates using the Security Torx Screws from Step 2.
12. Install the Power Adapter (
K
) onto the free end of the Power Cable. Make sure that the red wire (
positive
) is inserted into the
terminal under the (
+
) symbol and the black wire (
negative
) is inserted under the (
-
) symbol. Tighten the terminal screws down
on the wires and lightly tug on the wires to make sure they are held securely in place.
13. Plug the Transformer/Power Supply (
L
) into a normal wall outlet and insert its jack into the Power Adapter
(
K
)
.
The Transformer can be used for both 115V and 240V outlets (range of 100V to 240V). Optional plug adapters are available
for Europe (EUSS412) and Australia (AUWSS416).