Signal Generator:
Tracing the Direct Connected Signal
The tracing technique used to follow the Signal Generator
signal when applied by a direct connection method (Direct
Connection Leads, Signal Clamp or Signal Injector) is almost
exactly the same as the normal tracing technique used on
Power or Radio Modes but with the following differences:
The signal that the locator is detecting will get weaker the
further away from the Signal Generator that you go. It will be
necessary to regularly adjust (increase) the locator sensitivity
to compensate for this.
NOTE It is not possible to search for the signal above any leads connecting the Signal Generator to the service or
above the Earth Lead connected to the Earth Stake.
19