background image

- 1 -

I. Introduction

The tester is used for determine the resist pressure strength of concrete, brick, stone and other 
construction material. Load form is hydraulic pressure. The tester is applied to all college, 
construction unit of industrial and mining enterprises, the test force device adopts numeric display 
with micro printer, the test force part is compact, the shape is beauty, convenient to handle and 
maintain. 

II. Technical parameter

Maximum load 

2000 kN 

Measure range 

0-2000 kN

Up press plate size 

240mm×240 mm 

Down press plate size 

250mm×300 mm 

Press plate space 

320mm 

Maximum oil pressure 

40MPa 

Display value relative error 

±

1% 

Piston diameter* the farthest stroke 

Φ

250 mm×50 mm 

Electromotor power 

0.75kW (two-phase power supply) 

Exterior size(length*width*height) 

900×450×1320 mm 

Whole tester quality 

900kg 

. The tester be placed in clean, dry, without shake or without corrosive room, the surroundings

keep 0.5m space, level is not larger than 0.2mm/1000mm.The tester must touch ground
steadily.

. The power supply should steady, not over rated voltage 10%.

. Oil box adding oil use standard hydraulic oil (use N68 if room temperature over 25

, use N46

if room temperature under 25

)20 liter. Under normal circumstances change the oil once a

year, if use frequently or the environment not clean for six months to replace.

III.

 

Controller

Summary of Contents for SYE-2000BS

Page 1: ...I COMPRESSION TESTING MACHINE SYE 2000BS...

Page 2: ...I CONTENTS I Introduction 1 II Technical parameter 1 III Controller 1 IV Installation and operation 3 V Data Searching 5 VI Verification and Calibration 5 VII Troubleshooting 8...

Page 3: ...space 320mm Maximum oil pressure 40MPa Display value relative error 1 Piston diameter the farthest stroke 250 mm 50 mm Electromotor power 0 75kW two phase power supply Exterior size length width heig...

Page 4: ...ur minute Group setting 0001 9999 Codes of cross section of specimen setting 1 for 100 mm cubic compression specimen 2 for 150 mm cubic compression specimen 3 for 200 mm cubic compression specimen 4 f...

Page 5: ...rface is used for the communication with the computer if necessary Setting of the clock The time can be set as follows if necessary Date and time format is dd mm yyyy hh mm ss Press Func key continuou...

Page 6: ...orce Value window Press Enter key for cross section of the specimen setting input the code of the specimen e g if the 150 mm cubic specimen is placed on input 2 and then press Enter key to start a tri...

Page 7: ...rmation flashed and press Enter key P0000 and S 2 will be displayed on the windows Input the 4 digit and the code and press Enter key for searching E 01 will be displayed if the data can t be traced 4...

Page 8: ...ctual force value will be shown on the Loading Rate window Press Enter key when the value in the proving ring is the same with the standard value Repeat the procedures above for the next set loads ver...

Page 9: ...first set load is 200 kN input 200 and press Enter key for the next set load b 2 will be displayed on the Force Value window and repeat the procedure 2 1 3 for next set load The last set load is the o...

Page 10: ...e rear of the panel If the fuses are ok check if the input is normal The contactor is actuated but the motor does not run when the motor button is pressed on the panel No power supply to the motor Che...

Page 11: ...9...

Reviews: