Product information Wireless data loggers
29
TAB. 4: Capacity of the internal memory of the data logger in housing for indoor
Model
Number of samples that can
be stored
(**)
Minimum
logging interval
Stored quantities
(*)
HD35ED 7P/1 TC
68,000
1 s
T
HD35ED 7P/2 TC
from 52,000 to 68,000
2 s
(***)
T
HD35ED 7P/3 TC
from 42,000 to 68,000
5 s
(***)
T
HD35ED N/1 TC
68,000
1 s
T
HD35ED N/2 TC
52,000
1 s
T
HD35ED N/3 TC
42,000
1 s
T
HD35ED N TV
68,000
1 s
T
HD35ED 1 TV
68,000
1 s
RH
HD35ED 1 TVI
68,000
1 s
RH
HD35ED 1N TC
24,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35ED 17P TC
24,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35ED 1N TV
24,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35ED 1N TVI
24,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35ED 1N/2 TC
22,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35ED 1N/2 TCV
22,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35ED 14bN TC
22,000
2 s
T, RH, T
D
, T
W
, AH, MR, PVP, P
ATM
HD35ED 14bN TV
22,000
2 s
T, RH, T
D
, T
W
, AH, MR, PVP, P
ATM
HD35ED 14bN TVI
22,000
2 s
T, RH, T
D
, T
W
, AH, MR, PVP, P
ATM
HD35ED 1N4r…TV
22,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP,
D
P
HD35ED 4r…
68,000
1 s
D
P
HD35ED 1NI… TCV
44,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP, I
HD35ED 1NI TV
44,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP, I
HD35ED 14bNI… TCV
36,000
2 s
T, RH, T
D
, T
W
, AH, MR, PVP, P
ATM
, I
HD35ED 14bNI TV
36,000
2 s
T, RH, T
D
, T
W
, AH, MR, PVP, P
ATM
, I
HD35ED 1NIU TCV
32,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP, I, UVA, P
UV
HD35ED 1NIU TV
32,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP, I, UVA, P
UV
HD35ED1NUBTCV
44,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP, UVB
HD35ED1NUCTCV
44,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP, UVC
HD35ED 14bNIU TCV
32,000
2 s
T, RH, T
D
, T
W
, AH, MR, PVP, P
ATM
, I, UVA, P
UV
HD35ED 14bNIU TV
32,000
2 s
T, RH, T
D
, T
W
, AH, MR, PVP, P
ATM
, I, UVA, P
UV
HD35ED 1NB
44,000
10 s
T, RH, T
D
, T
W
, AH, MR, PVP, CO
2
HD35ED 1NAB
36,000
10 s
T, RH, T
D
, T
W
, AH, MR, PVP, CO, CO
2
HD35ED 14bNAB
32,000
10 s
T, RH, T
D
, T
W
, AH, MR, PVP, P
ATM
, CO, CO
2
HD35ED H
from 36,000 to 68,000
5 s
(***)
depends on the inputs configuration
(*)
List of the quantities:
T
: temperature
D
P
: differential pressure
RH
: relative humidity
I
: illuminance
T
D
: dew point
UVA
: UVA irradiance
T
W
: wet bulb temperature
UVB
: UVB irradiance
AH
: absolute humidity
UVC
: UVC irradiance
MR
: mixing ratio
P
UV
: proportion of UV present (µW/lumen)
PVP
: partial vapour pressure
CO
: carbon monoxide
P
ATM
: atmospheric pressure
CO
2
: carbon dioxide
(**)
One sample consists of all the quantities measured and calculated by the data logger at the same instant of acquisition. For example, the
model HD35ED1NAB measures four quantities and calculates five quantities (the derived humidity quantities) and one sample includes
one temperature measure, one CO measure, one CO
2
measure and six humidity measures (the relative humidity measure plus the five
derived quantities).
(***)
The minimum logging interval may be smaller if the data logger only stores some of the available quantities.