Product information Wireless data loggers
35
TAB. 7: Capacity of the internal memory of the data loggers in housing for
outdoor
Model
Number of samples that can
be stored
(**)
Minimum
logging interval
Stored quantities
(*)
HD35EDW
7P/1
TC
68,000
1 s
T
HD35EDW
7P/2
TC
from 52,000 to 68,000
2 s
(***)
T
HD35EDW
7P/3
TC
from 42,000 to 68,000
5 s
(***)
T
HD35EDW
N/1
TC
68,000
1 s
T
HD35EDW
N/2
TC
52,000
1 s
T
HD35EDW
N/3
TC
42,000
1 s
T
HD35EDW
N
TV
68,000
1 s
T
HD35EDW
K/4
TC
from 36,000 to 68,000
5 s
(***)
T
HD35EDW
1
TV
68,000
1 s
RH
HD35EDW
1
TVI
68,000
1 s
RH
HD35EDW
1N
TC
24,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35EDW
17P
TC
24,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35EDW
1N
TV
24,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35EDW
1N
TVI
24,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35EDW
1N/2
TC
22,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP
HD35EDW
14bN
TC
22,000
2 s
T, RH, T
D
, T
W
, AH, MR, PVP, P
ATM
HD35EDW
14b7P
TC
22,000
2 s
T, RH, T
D
, T
W
, AH, MR, PVP, P
ATM
HD35EDW
R
TC
42,000
1 s
R, D
R
, mV
HD35EDW
1NR
TC
24,000
1 s
T, RH, T
D
, AH, R, D
R
, mV
HD35EDW
7PR
TC
36,000
1 s
T, R, D
R
, mV
HD35EDW
1N7PR
TC
22,000
1 s
T, RH, T
D
, AH, R, D
R
, mV
HD35EDW
RP
TC
28,000
1 s
R, D
R
, mV, P, D
P
, I
P
HD35EDW
P
TC
36,000
1 s
P, D
P
, I
P
HD35EDW
NP
TC
28,000
1 s
T, P, D
P
, I
P
HD35EDW
1NP
TC
22,000
1 s
T, RH, T
D
, AH, P, D
P
, I
P
HD35EDW
1NL
TC
22,000
1 s
T, RH, T
D
, T
W
, AH, MR, PVP, H
LEAF
HD35EDW
S
TC
52,000
1 s
T, VWC
HD35EDW
S/2
TC
36,000
1 s
T, VWC
HD35EDW
S/3
TC
26,000
1 s
T, VWC
HD35EDW
DP
TC
28,000
1 s
F
L
, P
REL
, P, D
P
, I
P
HD35EDW
1NI2
TCV
30,000
1 s
T, RH, T
D
, AH, I
HD35EDW
1NB…
TV
30,000
1 s
(****)
T, RH, T
D
, AH, CO
2
HD35EDW
1NB…I…
TCV
26,000
1 s
(****)
T, RH, T
D
, AH, I, CO
2
HD35EDW
1NB…F
TCV
26,000
1 s
(****)
T, RH, T
D
, AH, PAR, CO
2
HD35EDW
WBGT
22,000
2 s
T, T
NW
, T
G
, RH, T
D
, WBGT
HD35EDW
H
from 28,000 to 58,000
5 s
(***)
depends on the inputs configuration
HD35EDW-MB
from 14,000 to 52,000
1 s
depends on the sensors connected
(*)
List of the quantities:
AH
: absolute humidity
P
ATM
: atmospheric pressure
CO
2
: carbon dioxide
P
REL
: relative pressure
D
P
: daily rainfall quantity
PVP
: partial vapour pressure
D
R
: daily solar radiation (Wh/m
2
)
R
: solar radiation (pyranometer)
F
L
: fluid level
RH
: relative humidity
H
LEAF
: leaf wetness
T
: temperature
I
: illuminance
T
D
: dew point
I
P
: rainfall rate (mm/h)
T
G
: globe thermometer temperature
MR
: mixing ratio
T
NW
: natural ventilation wet bulb temperature
mV
: pyranometer output in mV
T
W
: wet bulb temperature
P
: rainfall quantity
WBGT
: WBGT index
PAR
: Photosintetically Active Radiation
VWC
: soil volumetric water content
(**)
One sample consists of all the quantities measured and calculated by the data logger at the same instant of acquisition. For example,
the model HD35EDW1NTC measures two quantities and calculates five quantities (the derived humidity quantities) and one sample
includes one temperature measure and six humidity measurements (the relative humidity measure plus the five derived quantities).
(***)
The minimum logging interval may be smaller if the data logger only stores some of the available quantities.
(****)
CO
2
measurement is updated every 15 s.