that represent the command you want to enter. 94 alphanumeric characters may be entered for
each symbology data format.
Step 7.
Scan
Save
from the Programming Chart inside the back cover of this manual to save your
entries.
Other Programming Selections
Clear One Data Format
This deletes one data format for one symbology. If you are clearing the primary format,
scan 0 from the Programming Chart inside the back cover of this manual. If you are
clearing an alternate format, scan
1
,
2
, or
3
, depending on the alternate format you are
clearing. Scan the Terminal Type and Code I.D. (see Supported Terminals on page 21),
and the bar code data length for the specific data format that you want to delete. All other
formats remain unaffected.
Save
from the Programming Chart inside the back cover of this manual This exits, saving
any Data Format changes.
Discard
from the Programming Chart inside the back cover of this manual This exits
without saving any Data Format changes.
Data Format Editor Commands
Send Commands
F1 Send all characters followed by “xx” key or function code, starting from current cursor
position.
Syntax = F1xx
(xx stands for the hex value for an ASCII code, see ASCII
Conversion Chart (Code Page 1252), page 157.
F2 Send “nn” characters followed by “xx” key or function code, starting from current cursor
position.
Syntax = F2nnxx
(nn stands for the numeric value (00-99) for the number of
characters and xx stands for the hex value for an ASCII code. See ASCII Conversion
Chart (Code Page 1252), page 157.
F3 Send up to but not including “ss” character (Search and Send) starting from current
cursor position, leaving cursor pointing to “ss” character followed by “xx” key or function
code.
Syntax = F3ssxx
(ss and xx both stand for the hex values for ASCII codes, see
ASCII Conversion Chart (Code Page1252), page 157.
F4 Send “xx” character “nn” times (Insert) leaving cursor in current cursor position.
Syntax = F4xxnn
(xx stands for the hex value for an ASCII code, see ASCII Conversion
Chart (Code Page 1252), page 157, and nn is the numeric value (00-99) for the number of
times it should be sent.)
E9 Send all but the last “nn” characters, starting from the current cursor position.
Syntax
= E9nn
(nn is the numeric value (00-99) for the number of characters that will not be sent
at the end of the message.)
Move Commands
F5 Move the cursor ahead “nn” characters from current cursor position.
Syntax = F5nn
(nn stands for the numeric value (00-99) for the number of characters the cursor should
Summary of Contents for Colibri 5 Series
Page 94: ...Colibri serie 5 User s guide 2000 2008 C2R Technologie Sarl All rights reserved 94 94 Rev C...
Page 160: ...Colibri serie 5 User s guide 2000 2008 C2R Technologie Sarl All rights reserved 160 160 Rev C...
Page 161: ...Colibri serie 5 User s guide 2000 2008 C2R Technologie Sarl All rights reserved 161 Rev C...
Page 162: ...Colibri serie 5 User s guide 2000 2008 C2R Technologie Sarl All rights reserved 162 162 Rev C...
Page 163: ...Colibri serie 5 User s guide 2000 2008 C2R Technologie Sarl All rights reserved 163 Rev C...
Page 164: ...Colibri serie 5 User s guide 2000 2008 C2R Technologie Sarl All rights reserved 164 164 Rev C...
Page 165: ...Colibri serie 5 User s guide 2000 2008 C2R Technologie Sarl All rights reserved 165 Rev C...
Page 166: ...Colibri serie 5 User s guide 2000 2008 C2R Technologie Sarl All rights reserved 166 166 Rev C...
Page 168: ...Colibri serie 5 User s guide 2000 2008 C2R Technologie Sarl All rights reserved 168 168 Rev C...