Thank you for purchasing a CAAS Audio Elysian Pre-amplifier (EPre). The Elysian range have been 
designed to meet the highest standards of performance, sound and build quality.

The EPre should arrive in a well packaged box weighing slightly under 10kg. This should mean that your 
EPre arrives in pristine order. If this is not the case please contact your retailer immediately.

While unpacking, please take care to always lift with bent knees and a straight back, using your leg 
muscles to lift, in accordance with government HSE guidelines.

Installation

The EPre is a single chassis dual mono pre-amplifier. 

The EPre analogue audio circuitry operates in class A mode and therefore the EPre will operate warm to the 
touch. For this reason adequate ventilation is mandatory. Place the EPre in its preferred listening position, 
taking care to insure that it has adequate ventilation (CAAS recommend > 20cm all around & >30cm above), 
is not close to any heat radiating sources and is installed on an equipment stand capable of supporting in 
excess of 10kg weight.

Ensure when connecting the power cable that any extension leads necessary are rated at 13A or above. (Do 
not use extension cables unless absolutely necessary).

The Mains Supply

The EPre is available in two standard mains input versions; the 240V UK and European and the 120V USA. 
Please check the rear of your unit to make sure the right input voltage is marked.

The Input Output Options.

The EPre has two pairs of single ended (RCA) inputs and three pairs of balanced (XLR) inputs on the rear of 
the unit. All inputs are DC coupled from input to output (this is done for maximum sound quality) so please 
ensure that the source components do not exhibit a large output DC offset. 

When connecting the interconnect cables, observe the flow polarity of your cables. Only ever connect and 
disconnect the cables while the amplifier is powered off or in standby mode (front panel red LED illuminated). 
Take care not to short circuit the connectors or cables at any time as this may damage the EPre. Once you 
are certain that all cables are correctly fitted at both ends, you are ready to power up the EPre. 

Operation

Power the EPre up by turning the switch on the rear of the unit to the ON (I) position. This is a mechanical 
switch and will disconnect the product from the main supply. Once turned on the front red standby LED will 
illuminate (the EPre is in standby mode). Press and release the front panel standby button once (the button 
next to the red standby LED), this will switch the EPre ON and the first blue LED (input 1), on the other side 
of the volume control will illuminate. All the EPre audio circuity is powered down while in standby mode and 
only powered up when the EPre is fully switched on. Once switched on, the EPre may take as long as 20 
minutes to reach optimum performance. 

Once fully ON the EPre remote will operate and all functions can be accessed (volume up, volume down, 
input select and mute). To select a different input, press and release the input select button either on the 
remote or on the front of the unit (next to the blue LEDs at the right of the volume control). Each press will 
toggle to the next input so keep pressing and releasing until you have the right input. The input numbers on 
the front panel (above each LED) directly relates to the rear panel inputs.

Page 8

Summary of Contents for EPre

Page 1: ...CAAS Audio Elysian Pre amplifier EPre User Manual...

Page 2: ...ortant Precautions Mandatory 6 EPre Front Panel Explained 7 EPre Rear Panel Explained 7 Getting Started 8 Installation 8 The Mains Supply 8 The Input Output Options 8 Operation 8 Warm Up Period 9 Part...

Page 3: ...ist of just the relay switched volume control and a single or parallel for balanced zero feedback JFET buffer amplifier Volume control is achieved through a state of the art 128 step silver contact re...

Page 4: ...me input select and mute function CAAS Link 12V trigger for CAAS power amps DC Coupled from input to output Ultra linear ZERO feedback JFET Class A buffer stage for the purest signal transfer Switched...

Page 5: ...nput Impedance 27 kohms RCA 27 kohms per phase XLR Output Impedance 60 ohms per phase XLR 60 ohm RCA THD 0 01 1kHz 0dB level 2V RMS Crosstalk 90dB Output SNR A WTD 100dB Output DC Offset 1mV Power Con...

Page 6: ...gislated requirements As with all audiophile equipment the power cable should be the last item attached and the first item removed whenever equipment is added or removed from the audio chain Any cable...

Page 7: ...ts 1 2 3 4 5 and then back to 1 etc Input 1 is the default turn on selection These inputs can also be selected using the remote control EPre Rear Panel Explained 2 6 8 10 12 1 3 4 5 7 9 11 13 14 1 Mai...

Page 8: ...ts are DC coupled from input to output this is done for maximum sound quality so please ensure that the source components do not exhibit a large output DC offset When connecting the interconnect cable...

Page 9: ...S Link port When the CAAS Link cables are connected between the EPre and any CAAS Audio power amplifiers this connection will automatically power down the CAAS Audio power amplifier s When the standby...

Page 10: ...ts by a person or company other than CAAS Audio 3 Damage to CAAS Audio products arising due to or from normal wear and tear 4 Damage resulting from misuse neglect abuse accidents acts of nature improp...

Reviews: