Connections
Fig. 4f Connections
1
4
5
2
3
1. Prepare the connections to the power supply and to the computer
as described in the manual of the printer.
2. To contact the PLC interface use the 15-pin connector at the
manifold (for further details see appendix A).
3. Make sure that the shutoff valve (
5
) is closed (lever at the valve is
turned vertical).
4. The connector (
2
) for the compressed air supply is located at the
service unit (
1
) at the rear of the printer.
The connector is suitable for a 1/4" coupling plug (
3
).
5. The air pressure for operating the applicator has to be adjusted at
the service unit (
1
).
- Pull knurled knob (
4
) up.
- Turn knob to tune required operating pressure (5-6 bar).
By turning knob clockwise the pressure rises.
- Push knob down.
6. Switch on the power supply of the printer.
7. Open the shutoff valve. (
5
/ lever is turned horizontal)