Applicator - PLC Interface
A-1
cab - Produkttechnik GmbH & Co KG
Pin 9
Pin 15
Pin 8
Pin 1
Appendix A - PLC Interface
For use in a networked system the applicator is equipped with a PLC
interface to start and interrupt the labelling process. It also passes on
state information as well as error messages of the applicator to the
system control.
The interface has a 15 pin SUB-D connector.
Pin Assignment of the PLC Interface
Fig. A-1
Connector of the PLC Interface
PIN
Signal
Direction
Function
1
XSTRT
input
start signal
2
XSTP
input
stop signal
3
XDREE
input
print first label
4
XDNB
output
printer not ready
5
XEDG
output
no existing print job
6
XSAA
output
general error message
7
XSOE
output
pad in starting position
8
GND
output
grounding (0V)
9
XSTRTR
(input)
start signal (reverse line)
10
XSTPR
(input)
stop signal (reverse line)
11
XDREER
(input)
print first label (reverse line)
12
XSUE
output
pad in labelling position
13
XETF
output
applicator fault
14
RÜL
output
reverse line (for all output signals)
15
24P
output
operating v24V, Si T 100mA
Table A-1 Pin Assignment of the PLC Interface