Blow Applicator with Swing Cylinder
cab - Produkttechnik GmbH & Co KG
13
Side Adjustment
1. Loosen both bottom screws (
4
) on the rear side of the mounting
plate (
5
) of the blow applicator type 3100.
2. Move the cylinder unit (
2
) within the longish hole (
3
) until the
dispensed label is aligned centrally to the pad.
3. Tighten the screws (
4
).
Level Adjustment
1. Loosen both upper screws (
1
) on the rear side of the mounting
plate (
5
) of the blow applicator type 3100.
2. Move the cylinder unit until in its upper (starting) position the
pad (
6
) is located slightly above the dispense edge (
7
) of the
Apollo.
The distance between the pad and the dispense edge is
recommended to be around 1 mm.
3. Tighten screws (
1
).
1
2
3
4
5
6
7
Adjusting the Level and the Sides of the Cylinder Unit on the Apollo