Blow Applicator with Swing Cylinder
24
cab - Produkttechnik GmbH & Co KG
Print Info Display
Apollo
and
Hermes
offer a convenient option for recalling information
about the configuration and hardware problems in the printer info
display (see also Operator's Manual of the printer).
First, press the
key to switch from ONLINE mode into OFFLINE
mode. Next, to recall the printer information desired, press the
key to see the first of the five display pages available. Press key
repeatedly to view the other pages. When an applicator is installed,
this display is extended by another five pages. After the standard
pages, the following parameters are shown :
- start delay
- locking time
- switch-off delay supporting air
- blowing time
- switch-on delay supporting air.
When the reviewing is completed, switch back into ONLINE mode by
pressing the
key.
In case the applicator has been changed (e.g. in case of an accident)
the stored parameters can be viewed as described above and the new
device can be adjusted accordingly. For that purpose the DIP-switch 4
at the new applicator has to be 'ON' during switching on the device