14
14
5
Installation
5.1
Factory default Settings
i
Note!
The applicators default factory settings guarantee reliable operation within the same configuration.
The factory default settings are:
•
Connected to a cab HERMES Q printer, vertical
•
Used Pad for factory settings:
cab part No.: 5940831 25x10 for L
cab part No.: 5956410 25x10 for R
•
Material used for factory default settings:
cab part No.: 5556470 25x10
•
Pressure value of the compressed air:
0.45 MPa (4.5 bar)
•
Factory setting sensors
Cylinder Z
Cylinder R
•
Factory settings throttle valves
Cylinder Z
„6.8 Lift Speed of Cylinder Z“
Cylinder R
„6.12 Lift Speed of Cylinder R“
5.2
Tools
Screwdriver with parallel blade
2.5
•
To adjust the throttle valves
and product sensor
Hexagon key L-wrench
0.8
•
To adjust the sensors
(in contents of delivery)
2.5
•
For matched norm parts
(in contents of delivery)
4
•
Pad adjustments
Changing pad
Flat-round nose
- straight
- angled
•
To mount/dismount tubes
Open spanner
SW 8
•
To change the throttle valves
SW 13
•
Setting the spring strength of
the adapter bolt
SW20
•
Changing the cylinder
Manometer
± 7 bar
•
Air pressure control
Table 4
Tools