24
24
6.5
Vacuum Adjustments
The label will be held on the pad by a vacuum.
The vacuum needs to be set up in such a way that the label covers all the suction holes and is not hindered before it
reaches its intended position on the pad.
The default Value of the Vacuum is -0.6 bar.
support air
vacuum
1
Fig. 22
Throttle valve "vacuum"
Adjust the vacuum on the throttle valve "vacuum" (1) so that the label will be sucked up over its entire area.
To increase the vacuum turn the setting screw on the throttle valve (1) counterclockwise.
Measuring Point Vacuum (MP V)
MP V
1
2
3
Fig. 23
Measuring points for the vacuum
Use a manometer with a measurement range of -7 to
7 bar to control the pressure.
MP V : Vacuum - Reference Value (-0.6 bar)
1. Remove cover.
2. Cover the suction plate so it is airtight.
3. Attach manometer between tube (1) of the energy
chain and fitting (2) of the pad.
4. Activate the magnetic valve manually by pressing
the micro switch (3) to measure the pressure.
5. Mount cover.
!
Attention!
After pressure measurements, reconnect all components correctly.
Summary of Contents for 4214 Series
Page 1: ...Service Manual 4214 MADE IN GERMANY Stroke Turn Applicator...
Page 39: ...39 9 Drawings 9 2 Pneumatic Drawing Type 4214 Fig 43 Pneumatics type 4214...
Page 40: ...40 40 9 Drawings 9 3 Labeling Position Type 4214 L Fig 44 Labeling position 4214L...
Page 41: ...41 9 Drawings 9 4 Label Position Type 4214 R Fig 45 Labeling position 4214R...