10
10
1
1
2
2
6
7
3
4
5
Fig. 5
Mounting & dismounting the applicator on the printer
!
Attention!
Initiation, adjustments and changing of parts is to be performed by qualified service personnel only.
Service Manual Applicator
!
Attention!
Disconnect the printer from the power supply before mounting the applicator!
Ensure the printer is in a stable position!
Connect the compressed air only after mounting the applicator to the printer!
To clean the applicator and printer it's sometimes necessary to turn away or even dismount the applicator from the
printer.
Do not adjust the setting screws, throttle valves or other alignment elements. This will enable use of the applicator
directly after cleaning.
Turning away & dismounting the applicator
1. To turn away the applicator loosen thumbscrew (5) and swing the applicator to the side.
2. Disconnect SUB-D 15 male connector (6) from the female connector (7) of the printer.
3. Loosen screw (4) and move the locking plate (3) from the hinges.
4. Lift the applicator upward and off the printer.
Remounting the applicator
5. Hang the applicator via the female part (1) of hinges to the male printer mounted hinges parts (2).
6. Connect SUB-D 15 male connector (6) to the female connector (7) of the printer.
7. To secure the applicator slide the locking plate (3) under the hinge and tighten the screw (4).
8. Swing the applicator to the printer and tighten the thumbscrew (5).