16
17
7.3
Adjustments in the Printer Setup
3
2
1
4
Fig.8
Label transport / Reflex sensor
Waiting position of the label
The operation mode
"Blow"
must be selected in the setup. Only with this setting it is possible to change the
parameter
"Blow time"
.
After detecting the label (2) by the reflex sensor (1) it will be transported further for a defined time to reach the
pressure roll (4).
To change this overrun time use the parameter
> Blow time
A higher value causes a longer transport distance.
200 ms equates to 10 mm
Setup parameters of the applicator
Overrun of the label
If the label (2) has left the sensor area (3) it will be transported further for a defined time to apply the label completely
stressless. To change this overrun time use the parameter
> Support delay on
7.4
Signals
•
With the signal
DREE
will be started the print and transport to the waiting position of the label.
•
With the signal
START
will be started the application of the label on the product.
In the application mode
"Apply - Print"
the print of the next label starts directly after application of the previous
label.
In the application mode
"Print - Apply"
the signal DREE must be sent for each label.
Pin
Signal
Name
Description
Activation / Active Status
without applicator
with applicator
1
DREE
-
print first label in mode
"Apply-Print"
Switch on +24V between
Pin 1 and Pin 25
13
START
Print start signal
Precondition: The superior
control has confirmed with
the ETE signal that the
previous label has been
taken from the peel-off
position.
Start of printing and labeling +24V between Pin 13 and Pin 25
Interface description
Table 4
Part of the interface description of the label printer