14
14
5.3
Mounting and Dismounting the Applicator
9
2
10
3
4
6
1
7
5
8
Fig. 7
Mounting and dismounting the applicator
!
Attention!
Initiation, adjustments and changing of parts is to be performed by qualified service personnel only.
Service Manual Applicator.
!
Attention!
Disconnect the printer from the power supply before mounting the applicator!
Ensure the printer is standing securely in a stable position!
To clean the applicator and printer it is sometimes necessary to pivot away or even dismount the applicator entirely
from the printer.
Do not adjust the setting screws, throttle valves or other alignment elements as this will enable use of the applicator
directly after cleaning.
Dismounting the Applicator
1. Pull the power cable (7) out of the printer and power cable (5) out of the applicator.
2. Undo the screws (9) from the retainer (10).
3.
Hold the applicator firmly and loosen screws (6).
4. Move the applicator forward and pull the SUB-D connector (3) out of the socket (1) of the printer.
5. Detach the applicator by lifting it away.
Remounting the Applicator
6. Lift the applicator onto the printer and connect the SUB-D connector (3) to the socket (1).
7. Place the applicator onto the retainer (8). Push the applicator onto the printer so that the upper holes (4) of the
hinge plate are congruent to the holes (2) of the printer.
8. Insert and fasten screws (6).
9. Insert and fasten screws (9).
10. Connect power cables (5 and 7).