77
cab Produkttechnik GmbH & Co KG
M4
Character set
The parameter defines how different characters (symbols, letters, special
characters) will be translated to the interface.
Before operating the printer, the "Character set" of the printer should be
adapted to match the character set of the computer.
Adjustment is not possible with software. However, it is possible to use the
Unicode character table for characters which are not included in the selected
font.
RS-232 / Baud rate
When the printer is delivered, the RS-232 is configured for automatic baud rate
detection.
NOTICE !
For this method, after switching on the printer, the first sign of the serial
transmission must be odd. That means, that the lowest bit of the first
signs code must have the value "1". After that the baud rate rate is fixed
until the printer is switched off.
CABLABEL and cab Setup Utility guarantee, that the first sign is odd, when a
download of the configuration parameters is required. Therefore the Printer
Configuration is always possible, after the printer is switched on.
CAUTION !
Since it is not possible to guarantee the odd first sign under all
circumstances, it is recommended to choose a fixed baud rate before
starting the normal operation.
Table 8e Overview of the "Interfaces" Folder (continuation)
8. Printer Configuration
Parameter
Meaning
Ethernet (continuation)
LPD
Activation of the print service
LPD
Default :
Off
SNMP
Activation of the SNMP agent
Default :
Off
Timeserver
Connection to a Timeserver
Default :
Off
Ethernet error Selection, if Ethernet errors
should stop a print job
Default :
On
Selection
Off
On
Off
On
Off
On + IP of the Time-
server
On
Off