14
4.7
Changing the Control Panel / Emergency Switch
Danger!
Danger to life and limb from power supply.
Befor open the device unlink the power!
1
8
5
2
3
4
6
7
Fig.12 Dismount control panel / emergency switch
1. Dismount front and rear cover.
„Changing the hub to main motor“ on page 13
2. Pull out the connector (3) on the power supply to the
emergency switch.
3. Pull both Push-on-contacts (7) on the PCB to the
emergency switch.
4. Loosen screws (2).
5. Pull out connector (1) on the control panel (3).
6. Turn the lower part of the emergency switch (6) short only
approx. 10° and remove it.
7. Loosen nut (5) and remove the upper part (4) of the
emergency switch.
Mounting of the control panel (3) / emergency switch in
reverse order.
4.8
Changing the Belt
1
2
3
4
5
6
7
Fig.13 Changing the belt
1. Dismount front cover (1).
2. Loosen the three screws (6) and move the tension wheel (7) to the center to relax the belt (2) .
3. Loosen screws (5) and remove the upper catch plate (3).
4. Change the belt (2) and put it over the tension wheel and belt gear.
5. Put in the belt (2) so that the ends are between the lower catch plate (4) upper catch plate (3). but the both screw
holes must be free.
6. Put in screws (5) and tighten it.
7. Move the tension wheel (7) to th right side (outside), tension the belt (2) and tighten screws (6).
8. Mount the front cover (1).
4
Test and Change Device Parts