15
4.9
Changing the Energy Track
Danger!
Danger to life and limb from power supply.
Befor open the device unlink the power!
5
7
6
8
4
3
2
1
Fig.14 Energy track mount / dismount
1. Dismount the rear cover.
Page 13
2. Loosen screws (2) and remove PCB cover (1) .
3. Pull connector (3 and 4) and put out the cable from the cable retainer on the power supply (7) .
4. Loosen screws (4) and (8) .
5. Remove the energy track (7) .
Mounting the energy track (7) in reverse order.
4.10
Check the Sensors
Some sensors are integrated into the Maestro 4S to control the function and operation of the device.
This are reflex sensors with a switch reaction in case a surface are in front of approx. 3mm distance.
For changing and adjusting is a 5,5 mm jaw wrench necessary.
3mm
Fig.15
Reflex sensor
4