19
Parameter
Meaning
Default
Warn level labels
Only at HERMES Q!
Threshold diameter (80–240 mm) of the label supply roll, if the value is
undershot the "labels low" message will be activated.
Off
Pause on warning
The print job will be interrupted when the "labels low" message appears
Off
Table 6
Parameters of the
Setup > Labels
menu
Sensor kalibrieren
SQUIX / EOS / HERMES Q / PX Q
Start menu.
Select
Extras > Calibrate label sensor
.
The display shows
Step 1/2 Remove labels
.
Remove labels and select
Continue
.
After a few seconds the display shows
Step 2/2 Insert liner
.
Insert the liner without labels and select
Continue
.
After a few seconds the message
Sensor successfully calibrated
appears.
The display shows the characteristic values of the sensors e.g.
Brightness 12-28
.
Select
Continue
to quit the function.
MACH 4S
Start menu.
Select
Extras > Calibrate label sensor
.
The display shows
Step 1/4 Remove labels and ribbon
.
Perform step 1 and select
Continue
.
After a few seconds the display shows
Step 2/4 Insert liner
.
Perform step 2 and select
Continue
.
The display shows
Step 3/4 Remove liner, insert ribbon
.
Perform step 3 and select
Continue
.
The display shows
Step 4/4 Insert liner and ribbon
.
Perform step 4 and select
Continue
.
After a few seconds the message
Sensor successfully calibrated
appears.
The display shows the characteristic values of the sensors e.g.
Brightness 2-5 / 18-111
.
Select
Continue
to quit the function.