background image

Customer Care Australia P: 133 122 F: 1300 303 310 E: sales@cabac.com.au W: cabac.com.au 

A: 8 Distribution Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: sales@cabac.co.nz W: cabac.co.nz

3

3 of 21 

General safety instructions 

               

This    manual    contains    important    safety    instructions    that    should    be    followed   

during   the   installation   and   maintenance   of   the   UPS.       

Please   read   this   manual   thoroughly   before   attempting   to   install   or   operate   this   

UPS.   

DO    NOT    under    any    circumstances    attempt    to    remove    the    UPS    cover.    It    may   

contain   hazardous   voltages   internally   that   may   cause   electric   shock.   There   are   

no    user-­‐serviceable    parts    inside.    For    service,    please    contact    your    nominated   

service   agent.   

   

Conditions of Use 

This    equipment    is    designed    for    domestic    use    only.    The    manufacturer    neither   

recommends    nor    knowingly    sells    this    product    for    use    in    critical    life    support   

applications.       

1.

 

Intended   for   installation   in   a   controlled   environment.                   

a.

 

The   controlled   environment   should   be   in   accordance   with   

the   requirement   of   the   specification                   

b.

 

Do   not   install   or   operate   your   UPS   in   or   near   water.                   

c.

 

Do   not   place   UPS   on   an   unstable   cart,   stand   or   table.               

d.

 

Do    not    place    UPS    under    direct    sunlight    or    close    to    heat   

emitting   sources.                   

e.

 

Do   not   place   UPS   power   cord   in   any   area   where   it   may   get

   

Summary of Contents for UPS600DV3

Page 1: ...les cabac com au W cabac com au A 8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 1 Version 1 CABAC UNINTERRUPTIBLE POWER...

Page 2: ...co nz W cabac co nz 2 2 of 21 Contents General Safety Instructions 3 Conditions of Use 3 Electrical Safety 4 Safe Operating Practices 5 Battery Information 7 Introduction 8 Performance 8 Installation...

Page 3: ...in hazardous voltages internally that may cause electric shock There are no user serviceable parts inside For service please contact your nominated service agent Conditions of Use This equipment is de...

Page 4: ...e UPS cover It may contain hazardous voltages internally that may cause electric shock There are no user serviceable parts inside For service please contact your nominated service agent 1 The Cabac UP...

Page 5: ...nication port are kept separated by at least 25 mm from the power cords to and from the UPS input and output Safe Operating Practices This pluggable type A equipment has factory installed batteries an...

Page 6: ...P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 6 6 of 21 disconnected 5 Turn off and unplug your UPS from the outlet and contact your nominated service agent if o The power cord or plu...

Page 7: ...o the skin and eyes 3 A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other...

Page 8: ...r is used as the main controller that renders the product an intelligent UPS capable of self protection and fault diagnosis A built in AVR function automatically adjusts itself to maintain a power sup...

Page 9: ...ction When the UPS is turned ON it immediately performs an inspection of the battery capacity Automatic Voltage Regulation Corrects over and under voltages without draining the battery This preserves...

Page 10: ...temperature and humidity is outside the specified limits in the Specifications Table 3 Connect to Mains Power Connect the AC input power cord to a socket outlet to power up the UPS The battery in the...

Page 11: ...cabac co nz W cabac co nz 11 11 of 21 Physical Appearance Front Panel Rear Panel Item Description 1 On Off Power Switch 2 LED 1 GREEN AC Normal Status LED 3 LED 2 YELLOW Battery Charging LED 4 LED 3 R...

Page 12: ...dicators Front Panel Indicator Buzzer Status Operational Description LED 1 Green LED2 Yellow LED 3 Red OFF ON OFF OFF UPS OFF Mains Normal Batteries Charging ON ON OFF 2 second Interval Beeping UPS ON...

Page 13: ...s the power switch to stop the beeping The alarm stops when the UPS returns to normal utility mode of operation Low Battery Beeping 2 times every 1 second In Backup mode when the battery energy runs l...

Page 14: ...750W Input Characteristics Rated Input Voltage 230 240V Input Voltage Range 165 275 V Rated Input Frequency 50 Hz 10 Output Characteristics Rated Output Voltage 230V 10 Output Frequency 50 Hz 10 Outpu...

Page 15: ...mm x 124mm x 382mm Operating Temperature 10 C to 40 C Maximum Operating Relative Humidity 95 Relative Maintenance 1 With normal use a UPS battery will last 2 to 3 years depending on the number of disc...

Page 16: ...es cabac co nz W cabac co nz 16 16 of 21 Software Installation In order to utilise the UPS to its full potential the monitoring software must first be installed Please install the software according t...

Page 17: ...stribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 17 17 of 21 3 Enter details as requested on this screen Your product serial n...

Page 18: ...sales cabac com au W cabac com au A 8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 18 18 of 21 5 Select language English...

Page 19: ...8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 19 19 of 21 7 Installation is now complete Click FINISH 8 The program is...

Page 20: ...No LED s on i Battery Discharged Sleep Mode Press the POWER button ON ii PCB failure Contact Service Agent UPS always at battery mode Power cord lose Re plug the power cord Line voltage too high too l...

Reviews: