background image

Customer Care Australia P: 133 122 F: 1300 303 310 E: sales@cabac.com.au W: cabac.com.au 

A: 8 Distribution Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: sales@cabac.co.nz W: cabac.co.nz

4

4 of 21 

damaged   by   heavy   objects.       

2.

 

Placing    magnetic    storage    media    on    top    of    the    UPS    may    result    in    data   

corruption.   

3.

 

Your   UPS   provides   conditioned   power   to   connected   equipment.   Maximum   

load    must    not    exceed    that    shown    on    the    UPS    rating    label.    If    uncertain,   

contact   Legend   

       

Electrical Safety 

   

DO    NOT    under    any    circumstances    attempt    to    remove    the    UPS    cover.    It    may   

contain   hazardous   voltages   internally   that   may   cause   electric   shock.   There   are   

no    user-­‐serviceable    parts    inside.    For    service,    please    contact    your    nominated   

service   agent.   

   

1.

 

The   Cabac   UPS   will   provide   a   220~240VAC   1φ

single-­‐phase

rate   power   

source.   Please   verify   that   this   model   matches   your   AC   mains   /   load   voltage   

requirements.   

2.

 

The   Cabac   UPS   must   be   earthed   at   all   times   during   operation.   This   can   be   

achieved    by    only    connecting    the    input    power    chord    to    a    mains    supply   

socket   outlet   with   an   integral   earth   terminal.   A   means   of   disconnecting   the   

mains   supply   should   be   within   2   meters   of   the   UPS.   

3.

 

Output   sockets   on   the   UPS   are   electrically   live   if   the   UPS   is   switched   ON,   

even   if   the   UPS   is   not   plugged   in   to   mains   supply.   The   On/Off   button   on   

Summary of Contents for UPS600DV3

Page 1: ...les cabac com au W cabac com au A 8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 1 Version 1 CABAC UNINTERRUPTIBLE POWER...

Page 2: ...co nz W cabac co nz 2 2 of 21 Contents General Safety Instructions 3 Conditions of Use 3 Electrical Safety 4 Safe Operating Practices 5 Battery Information 7 Introduction 8 Performance 8 Installation...

Page 3: ...in hazardous voltages internally that may cause electric shock There are no user serviceable parts inside For service please contact your nominated service agent Conditions of Use This equipment is de...

Page 4: ...e UPS cover It may contain hazardous voltages internally that may cause electric shock There are no user serviceable parts inside For service please contact your nominated service agent 1 The Cabac UP...

Page 5: ...nication port are kept separated by at least 25 mm from the power cords to and from the UPS input and output Safe Operating Practices This pluggable type A equipment has factory installed batteries an...

Page 6: ...P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 6 6 of 21 disconnected 5 Turn off and unplug your UPS from the outlet and contact your nominated service agent if o The power cord or plu...

Page 7: ...o the skin and eyes 3 A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other...

Page 8: ...r is used as the main controller that renders the product an intelligent UPS capable of self protection and fault diagnosis A built in AVR function automatically adjusts itself to maintain a power sup...

Page 9: ...ction When the UPS is turned ON it immediately performs an inspection of the battery capacity Automatic Voltage Regulation Corrects over and under voltages without draining the battery This preserves...

Page 10: ...temperature and humidity is outside the specified limits in the Specifications Table 3 Connect to Mains Power Connect the AC input power cord to a socket outlet to power up the UPS The battery in the...

Page 11: ...cabac co nz W cabac co nz 11 11 of 21 Physical Appearance Front Panel Rear Panel Item Description 1 On Off Power Switch 2 LED 1 GREEN AC Normal Status LED 3 LED 2 YELLOW Battery Charging LED 4 LED 3 R...

Page 12: ...dicators Front Panel Indicator Buzzer Status Operational Description LED 1 Green LED2 Yellow LED 3 Red OFF ON OFF OFF UPS OFF Mains Normal Batteries Charging ON ON OFF 2 second Interval Beeping UPS ON...

Page 13: ...s the power switch to stop the beeping The alarm stops when the UPS returns to normal utility mode of operation Low Battery Beeping 2 times every 1 second In Backup mode when the battery energy runs l...

Page 14: ...750W Input Characteristics Rated Input Voltage 230 240V Input Voltage Range 165 275 V Rated Input Frequency 50 Hz 10 Output Characteristics Rated Output Voltage 230V 10 Output Frequency 50 Hz 10 Outpu...

Page 15: ...mm x 124mm x 382mm Operating Temperature 10 C to 40 C Maximum Operating Relative Humidity 95 Relative Maintenance 1 With normal use a UPS battery will last 2 to 3 years depending on the number of disc...

Page 16: ...es cabac co nz W cabac co nz 16 16 of 21 Software Installation In order to utilise the UPS to its full potential the monitoring software must first be installed Please install the software according t...

Page 17: ...stribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 17 17 of 21 3 Enter details as requested on this screen Your product serial n...

Page 18: ...sales cabac com au W cabac com au A 8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 18 18 of 21 5 Select language English...

Page 19: ...8 Distribution Pl Seven Hills NSW 2147 Customer Care New Zealand P 8 0077 6969 F 8 0088 6969 E sales cabac co nz W cabac co nz 19 19 of 21 7 Installation is now complete Click FINISH 8 The program is...

Page 20: ...No LED s on i Battery Discharged Sleep Mode Press the POWER button ON ii PCB failure Contact Service Agent UPS always at battery mode Power cord lose Re plug the power cord Line voltage too high too l...

Reviews: