QS-200 Instruction Manual  

 

 

OPERATING INSTRUCTIONS 

INTRODUCTION 

This section covers instructions for using the QS-200S. 

FRONT AND REAR PANEL FEATURES 

A description of the front and rear panel features is provided earlier in the manual in the section Operating 
Controls & Indicators.  All controls, indicators, and connectors are identified and briefly described.  (See 
Figure 1.)   

BEFORE INITIAL POWER-ON 

Check the rear panel label to verify the instrument operating voltage.  Correct line voltage is 

very

 

important.   

The offset pin of the power cable is provided to ground the instrument when plugged into the appropriate 
receptacle.  (Satisfactory operation of the QS-200S requires the instrument to be grounded.) 

POWER-ON PROCEDURE & MODE SELECTION 

Selection of the instrument operating mode is accomplished by depressing either the SCAN, ANALYZE, 
or PRESELECT interlocked mode switches. 

SCAN MODE 

With the SCAN switch depressed, the QS-200S operates with a short dwell time.  If a single wire is 
contacted, the display will show the coded number corresponding to the wire contacted.  (The code is 
determined by the interface cable assembly connecting the wire network to the QS-200S).  Contacting 
multiple wires simultaneously, however, causes the numbers to be rapidly sequenced through.  This 
appears as a flickering of the numeric display. 

ANALYZE MODE 

The ANALYZE Mode is used when the identity of multiple wires (as indicated in SCAN) is to be 
determined.  Depressing the ANALYZE switch sets the instrument for this purpose.  A decimal-point 
light appears to the right of the display continuously to alert the operator that this mode has been selected.  
The identities of all wires contacted are now sequentially displayed on the LED readout.   

PRESELECT MODE  

The PRESELECT Mode is used to identify only one wire in a bundle.  When this mode is selected, only 
the wire preselected on the thumbwheel switch is displayed.  Whenever any other wire is probed, only the 
decimal point to the right of the hundreds digit will flash.  If the preselected wire is probed in addition to 
any other wires, the decimal point will flash in addition to the preselected number on the display.  In 
addition, if the preselected wire is shorted to any other wire, the decimal point will flash.   

INTERFACE TO WIRE ASSEMBLY 

Four interface connectors are provided on the rear panel.  These furnish the inputs from the wire 
assembly.  The interface cables that connect the wire assembly to the QS-200S set the code; i.e., the 
number associated with any wire in the network.  The set of numbers provided are 1, 2, to 200.   

Summary of Contents for QS-200S

Page 1: ...ELECTRONIC ASSEMBLY AID QS 200S Cablescan ...

Page 2: ......

Page 3: ...March 25 2005 QS 200S INSTRUCTION MANUAL Part Number 5900159 Cablescan A Eubanks Company 3022 Inland Empire Blvd Ontario California 91764 909 483 2436 Fax 909 483 2463 www cablescan com ...

Page 4: ... and fitness for use and under no circumstances shall Cablescan Inc be liable for any incidental or consequential property damages or losses If the product is within the warranty period and requires repair for any defect of manufacture contact your Cablescan Inc representative for instructions on returning it to the factory If the product is beyond the warranty period and repair is necessary it is...

Page 5: ...rument Positioning 1 Repair 1 OPERATING CONTROLS INDICATORS 2 OPERATING INSTRUCTIONS 4 Introduction 4 Front and Rear Panel Features 4 Before Initial Power On 4 Power on Procedure Mode Selection 4 Scan Mode 4 Analyze Mode 4 Preselect Mode 4 Interface to wire Assembly 4 MAINTENANCE 5 Disassembly Assembly 5 Adjustments 5 Trouble Analysis 5 ...

Page 6: ...ed in place of existing color letter or alphanumeric designations The QS 200S is a compact self contained instrument using body conductance to allow unmatched versatility in identifying any wire at random Two hundred signal inputs are provided on four connectors of 50 pins each Contact of the probe output to any input will produce a three digit display of the number assigned to that particular inp...

Page 7: ... rate when multiple wires are present MULTIPLE WIRES At least 20 wires displayed POWER 104 to 126 V 50 60 Hz or 208 to 252 V 50 60 Hz internally selectable 4 watts maximum power OPERATING TEMPERATURE 32 F to 105 F 0 C to 40 C STORAGE TEMPERATURE 40 F to 165 F 40 C to 74 C DIMENSIONS 10 2 x 11 0 x 3 2 inches 25 9 x 27 9 x 8 2 cm WEIGHT 5 5 pounds 2 49 Kg DISPLAY 0 270 inch LED Numeric Readout Speci...

Page 8: ......

Page 9: ...he circuit breaker switch position Contact with these points may result in personal injury or death Therefore always disconnect the power cord when changing power transformer connections For the purpose of changing transformer line voltages perform the following steps to expose the power transformer a Loosen side knobs and remove handle positioner b Place instrument upside down and remove four scr...

Page 10: ... SWITCHES A set of three thumbwheel switches allows for the preselection of any wire from 001 through 200 DISPLAY A three digit visual readout of the corresponding pin on scan inputs connected to PROBE Note Decimal point to the right of the units display indicates operation in the ANALYZE mode Decimal point to the right of the hundreds display indicates a wire probed in the PRESELECT mode other th...

Page 11: ...Q S 200S E AR P H O N E V O LU M E W IR E N U M B E R P R E S E LE C T S C A N A N A LY ZE 0 4 3 P R O B E Front Panel J2 J4 J1 J3 151 200 101 150 1 50 51 100 Q S 2 00S S N X X X X Cablescan Inc Made in U S A PUSH ON Rear Panel Figure 1 ...

Page 12: ...ting multiple wires simultaneously however causes the numbers to be rapidly sequenced through This appears as a flickering of the numeric display ANALYZE MODE The ANALYZE Mode is used when the identity of multiple wires as indicated in SCAN is to be determined Depressing the ANALYZE switch sets the instrument for this purpose A decimal point light appears to the right of the display continuously t...

Page 13: ...inals The energy available at those points may result in personal injury or death if contacted ADJUSTMENTS The QS 200S has no adjustments TROUBLE ANALYSIS Trouble shooting the QS 200S will be much easier after obtaining a good basic knowledge of the instrument Trouble analysis should be undertaken only after it is established that a malfunction exists Check to be sure that the trouble is not the r...

Page 14: ...Page 6 QS 200 Instruction Manual NOTES ...

Page 15: ...5900159 Rev F Cablescan ...

Reviews: