background image

 

Quick Start Guide 

200-2470 v1 

3/16 

 

The IP netmask, gateway and DNS server can be set in the same way.  It is important to set the 

gateway and DNS server addresses if domain host names are to be used for stream routing.   

The MAC address of the unit can be found under the Unit Details/ MAC Address menu, or on the label on 

the bottom face of the unit. 

 

If a DHCP allocated IP address is required, navigate the menus to the IP Settings 

 DHCP menu and 

press OK to select DHCP.  The display will show the allocated IP address details once a lease has been 

obtained. 

 

6.  Plug the Re-Caster into the LAN switch using the CAT5 patch cable supplied.  It will Auto-negotiate up 

to a 1000 Mbps link with your network switch.  This unit can be used with a 100Mbps network switch, 

but it is recommended that the total outbound data rate does not exceed 80Mbps (the network usage 

can be found on the Re-

Caster’s Status web page).

 

 

7.  Connect to the LAN-

Caster’s configuration web pages using a PC

/MAC and Web browser software 

(e.g. Edge, Chrome or Firefox), by entering the Re-

Caster’s IP address into the browser’s address bar.  

Click through any warnings and the Re-

Caster’s specification page will then be shown.

 

 

8.  Click on the Date/Time page link on the left-hand side panel and set up an NTP time server.  If no 

local time server is available, the internet based pool.ntp.org server is recommended.  Ensure the Re-

Caster’s network settings have been configured to allow it access to the internet.

 

 

9.  Click on the Routing page link on the left-hand side panel and configure the Re-Caster for use.  There 

is no limit to the number of simultaneous Routes that can be configured; however, users should ensure 

the CPU Memory and Network usage indicators on the status page do not go far above 80% in use.  This 

provides a margin to allow for any transient peak conditions.  If the capacity of the Re-Caster is 

exceeded, TV picture disruption may occur. 

 

The status page usage indicators keep the peak readings previously seen.  These peaks can be reset on 

the Enablement web page by clicking the appropriate check box followed by Apply. 

 

 

 

 

Summary of Contents for MediaStar 799

Page 1: ...cific multicast streams and converts them to unicast streams for transition across a VPN When the unicast stream reaches the Re Caster on the remote side of the VPN link it converts it back to a multicast stream for LAN transmission to settops and PC MAC clients which show the TV pictures What s in the box 799 IP Re Caster Blade CAT5 Patch cable When only a regular internet connection is available...

Page 2: ... gently push it in As the module reaches the back of the 770 rack the plastic aperture cover on the rear of the rack will be pushed off by the Blade s HDMI connector Collect the discarded aperture cover and dispose of it correctly If the rack or chassis is powered up the new module will power up as it is pushed in If the rack has been powered down repower it now The status LED on the front of the ...

Page 3: ...ion web pages using a PC MAC and Web browser software e g Edge Chrome or Firefox by entering the Re Caster s IP address into the browser s address bar Click through any warnings and the Re Caster s specification page will then be shown 8 Click on the Date Time page link on the left hand side panel and set up an NTP time server If no local time server is available the internet based pool ntp org se...

Page 4: ...QoS then an SRT link can be set up over the VPN SRT will perform any packet re ordering or lost packet retransmission so a good quality remote picture is produced at the destination site To set up an internet based SRT link from site A to sites B and C configure the Re Caster routing table on Site A as follows 1 Click on the Routing web page link on the left hand side panel 2 Check the Enable Sour...

Page 5: ...n Apply the settings 8 After a few seconds check that an incoming data rate is shown near the bottom of the Route entry right pointing arrow This indicates the Re Caster is successfully accessing the incoming IP TV stream If this remains at zero check the correct IP address or host name of the device providing the stream has been set click on the Source field list box symbol After that disable App...

Page 6: ...he logical name for the route in the Route name field Channel 1 shown here and then Apply the settings 7 As before after a few seconds the incoming and outgoing stream data rates will be shown so you can see the SRT connection has been made and the outgoing stream is making its way onto the LAN If the SRT connection cannot be established with the remote site then an error message will be shown on ...

Page 7: ...N which will then correct the packet losses The cost of this is an additional second of stream transfer latency and the ability to transfer fewer IP TV streams per Re Caster pair To set up a VPN link from site A to sites B and C configure the Re Caster routing table on Site A as follows 1 Click on the Routing web page link on the left hand side panel 2 Check the Enable Source checkbox Select the U...

Page 8: ...y the source to re join the incoming multicast stream The outgoing data rate left pointing arrow will reflect the total outgoing data rate of that TV channel On Sites B and C the Re Casters that want to access the Channel 1 stream over the VPN link should be configured as follows 1 Click on the Routing web page link on the left hand side panel 2 Check the Enable Source checkbox Select the UDP sett...

Page 9: ...ttings for the multicast stream 6 Enter the logical name for the route in the Route name field Channel 1 shown here and then Apply the settings 7 After a few seconds check that an incoming data rate is shown near the bottom of the Route entry right pointing arrow This indicates the Re Caster is successfully accessing the incoming IP TV stream If this remains at zero check the correct IP address of...

Page 10: ...s Re Caster 3 Click on the list box symbol at the right hand end of the Source field Enter the IP address or host name of the Encoder or LAN Caster device that is sending the IP stream not the stream address The Re Caster will check all the stream data being transferred comes from that device Any stream data that comes from another IP address will not be forwarded 4 Check the Enable destination ch...

Page 11: ... used with the three adjacent push buttons to view status information and configure the operation of the unit The UP and DOWN buttons scroll up and down the menus and change parameter values The OK button selects the currently displayed menu item or confirms a parameter change Pressing the UP and DOWN buttons and releasing them together returns up a menu level usually aborting a parameter change T...

Page 12: ...dress Subnet Mask and Gateway settings Confirm these with the network administrator before configuring Update Locations This is the URL of the MediaStar http server and folder that the Re Caster will look at for software updates and configuration files It will normally automatically be set by the Media Manager server The Re Caster will only accept new software that has been digitally signed by Cab...

Page 13: ...am replication the Re Caster has a 600 Mbps input output capacity link buffering latency 250 mS For SRT links the Re Caster has a total SOURCE capacity of 160 Mbps or a total RECEIVER capacity of 120 Mbps or a TX RX combination of these link buffering latency 1000 mS USB USB 3 0 host port used for keyboard Mouse software upgrade via memory stick HDMI Port Re Caster status information displayed on ...

Page 14: ...Quick Start Guide 200 2470 v1 14 16 Notes ...

Page 15: ...ity characteristics EN61000 3 2 2014 Electromagnetic compatibility Limits for harmonic current emissions EN61000 3 3 2013 Limitation of Voltage changes voltage fluctuation and flicker IEC 60950 1 2005 A1 2009 A2 2013 Information Technology Equipment Safety Requirements EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 UL 60950 1 2007 R 2014 10 CAN CSA C22 2 No 60950 1 2007 A2 2014 10 IEC 62368 1 2...

Page 16: ...that the product and its electronic accessories should not be disposed of with other household waste at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Whilst all reasonable care has been t...

Reviews: