Removing the Chassis Cover
2H22-08R SmartSwitch 2208 User’s Guide
Page C-5
C.2.1
Setting the Mode Switch
Figure C-2
shows the location of the mode switches and the switch
settings for normal operation. These switches are set at the factory and do
not need to be changed.
Figure C-2
Mode Switch Location/Component Layout
Switch definitions and positions are as follows:
•
Switches 1 through 4 – For Cabletron Systems use only.
•
Switch 5 – COM Port Autobaud. The default (OFF) position enables
Autobaud sensing on the COM port for Local Management sessions.
Changing the switch to the ON position disables Autobaud sensing and
sets the COM port to 9600 baud for Local Management sessions.
2251-05
Flash
DRAM
MODE SWITCH BANK
1
2
3
4
5
6
7
8
OFF
ON
FRONT PANEL
TOP VIEW WITHOUT COVER
Primary
Power
Supply
Redundant
Power
Supply