Chapter 3: LM Security Screens for 2H23-50R/2H33-37R Devices
3-8
Local Management Supplement
The following section defines the fields on the Module Level Security
Configuration screen.
Connector (Read-Only)
Indicates the connector. Refer to
Table 3-3
for the connector
(CONN)/repeater port relationship on the device.
Security State (Selectable)
Used to set all ports on an interface connector to the same security state.
PortMismatch is a Read-Only field that indicates not all ports on the
interface connector are set to the same state. The selectable states are as
follows:
•
NonSecure – Allows the ports on the connector to receive all frames.
The source address of received frames is not examined and the frames
are processed in a non secure state.
•
LockOnNext – The next frame received by each port is examined to
learn its source address. After the source address of a frame is learned
on a port, it is now locked on that address and only those frames
received with that same source address are allowed on that port. All
frames received that do not have that same source address will cause
the device to execute the actions selected in the Action On Intruder
field.
Table 3-3
CONN/Repeater Port Relationship
2H23-50R
2H33-37R
CONN 1 = Repeater ports 1 – 12
CONN 1 = Repeater ports 1 – 12
CONN 2 = Repeater ports 13 – 24
CONN 2 = Repeater ports 13 – 24
CONN 3 = Repeater ports 25 – 36
CONN 3 = Repeater ports 25 – 36
CONN 4 = Repeater ports 37 – 48