Chapter 3: Configuring the 3F00-01 and 3F55-01
Page 3-4
FDDI Dual-Attached Intelligent Module User’s Guide
•
fddimibMACLostCts
– A count of the number of instances that this
MAC detected a format error during frame reception such that the
frame was stripped (corresponds to ANSI {fddiMAC 82}, refer to
ANSI MAC 7.5.3). Any attempt to write this parameter will cause the
MAC’s
Frame_Ct
,
Copied_Ct
,
Transmit_Ct
,
Error_Ct
, and
Lost_Ct
to
be zeroed.
Some of the SMT version 7.3 MIB variables (
fddimibSMT 2
) have had
their access types restricted from Read-Write to Read-Only. The variables
with restricted access include:
•
fddimibSMTConfigPolicy
– A value that indicates the configuration
policies currently desired in a node (corresponds to ANSI {fddiSMT
26}). This is always 0.
•
fddimibMACRequestedPaths
– List of permitted paths which specifies
the path(s) into which the MAC may be inserted (corresponds to ANSI
{fddiMAC 32}, refer to ANSI SMT 9.7). Only default setting as
defined in SMT 9.7 is supported.
•
fddimibPORTConnectionPolicies
– A value representing the port’s
connection policies desired in the node (corresponds to ‘none’, the
second octet to ‘tree’, and the third octet to ‘peer’.
Variables in the SMC enterprise MIB can be set to specify under what
conditions traps should be sent to an NMS. (Refer to the ATX MIB
Reference Guide for more detailed information.) Those variables include:
•
sfddiSmtConditions
– SMT conditions which should be reported to
the NMS via SNMP traps.
•
sfddiSrfConditions
– SRF conditions which should be reported for
the NMS via SNMP traps.
In the SMC enterprise MIB, you can set a variable to connect to port B:
•
sfddiThruB
– Whether to connect to the FDDI port B (not applicable
for single-attached stations).
Summary of Contents for 3F00-01
Page 2: ......
Page 10: ...Contents viii FDDI Dual Attached Intelligent Module User s Guide ...
Page 62: ...Chapter 6 Adding Swapping Modules Page 6 4 FDDI Dual Attached Intelligent Module User s Guide ...
Page 66: ...Appendix A Technical Specifications Page A 4 FDDI Dual Attached Intelligent User s Guide ...
Page 68: ...Appendix B Cabling Information Page B 2 FDDI Dual Attached Intelligent Module User Guide ...