Chapter 4: Monitoring and Managing the 3F00-01 and 3F55-01
Page 4-12
FDDI Dual-Attached Intelligent Module User’s Guide
•
Of this MAC’s paths, the greatest lower bound of
TVX
supported.
Every MAC has just one path, so this is simply the lower bound of
TVX
,
which is always -255. [
snmpFddiMACTVXGreatestLowerBound
]
•
The paths available for this MAC. This is none (0), unless the FDDI
ring is operational (
Ring_Op
is True), in which case this is the Primary
(1) path. [
snmpFddiMACCurrentPath
]
•
The current path associated with this MAC. This is isolated (16),
unless the FDDI ring is operational (
Ring_Op
is True), in which case
this is the Primary (2) path. [
snmpFddiMACCurrentPath
]
•
The MAC address of this MAC’s upstream neighbor.
[
snmpFddiMACUpstreamNbr
]
•
Whether the upstream neighbor is a Station or a Concentrator.
[
snmpsmtUpstreamDescriptor
]
•
The topology state of this station on the ring which may be one or more
of the following: [
snmpsmtUpstreamState.Topology
]
-
Station is wrapped
-
Station is an unrooted concentrator
-
Station is in a twisted ring
-
Station is a rooted station
•
Whether a duplicate address was detected by this station or its
upstream neighbor. [
snmpsmtUpstreamState.Dup1Address
]
•
The date/time the NMS read this duplicate address detected condition.
This date/time is not the same as the date/time the port detected the
condition.
•
The MAC address of this MAC’s previous upstream neighbor.
[
snmpFddiMACO1dUpstreamNbr
]
•
The current status of this MAC’s Duplicate Address Test.
[
snmpFddiMACDupAddrTest
]
Summary of Contents for 3F00-01
Page 2: ......
Page 10: ...Contents viii FDDI Dual Attached Intelligent Module User s Guide ...
Page 62: ...Chapter 6 Adding Swapping Modules Page 6 4 FDDI Dual Attached Intelligent Module User s Guide ...
Page 66: ...Appendix A Technical Specifications Page A 4 FDDI Dual Attached Intelligent User s Guide ...
Page 68: ...Appendix B Cabling Information Page B 2 FDDI Dual Attached Intelligent Module User Guide ...