SmartSwitch 9000-6 Slot Chassis Installation
2-10
Installing SmartSwitch 9000-6 Slot Interface Modules
SmartSwitch 9000 Interface Modules can be installed in any of the six slots that
are available. To install Interface Modules, see Figure 2-3 and follow the steps
below:
1. Remove the blank plate, covering the slot in which the Interface Module will
be installed. All other slots must remain covered to ensure proper airßow and
cooling. (Save the blank plate in the event you need to remove the module.)
2. Unpack the Interface Module by carefully removing it from the shipping box.
(Save the box and packing materials in the event the module must be
reshipped.)
3. Remove the Interface Module from the plastic bag. (Save the bag in the event
the Interface Module must be reshipped.)
4. Examine the Interface Module, carefully checking for damage. If any damage
is evident, DO NOT install the Interface Module. Contact Cabletron Systems
Global Call Center immediately.
5. Install the Interface Module in the chassis by aligning the module card
between the upper and lower metal rail guides of any available slot, sliding it
into the chassis, and locking down the top and bottom plastic tabs, as shown
in Figure 2-3. Take care that the Interface Module slides in straight and
properly engages the backplane connectors.
Observe all antistatic precautions when handling sensitive electronic equipment.
!
CAUTION
Summary of Contents for 9C106
Page 1: ...9031993 02 SmartSwitch 9000 6 Slot 9C106 and 9C706 Chassis Setup and Installation Guide ...
Page 2: ......
Page 6: ...Notice iv ...
Page 18: ...Introduction 1 10 ...
Page 30: ...SmartSwitch 9000 6 Slot Chassis Installation 2 12 ...
Page 34: ...9C206 1 Power Supply Operation 3 4 ...
Page 40: ...SmartSwitch 9000 6 Slot Chassis Security Bars A 4 ...