background image

 

9032058-01

 

SmartSwitch 9000

9F426-03

Local Management Appendix

Summary of Contents for 9F426-03

Page 1: ...9032058 01 SmartSwitch 9000 9F426 03 Local Management Appendix ...

Page 2: ......

Page 3: ...aces Table 1 lists the identifying number name and description of each interface Table 1 9F426 03 FDDI Switch Module Interfaces Interface Number Interface Name Interface Description 1 SMB1 1 Mbps System Management Bus 2 SMB10 10 Mbps System Management Bus 3 HOST i960 Host 4 CONTROL i960 Data Controller 5 INB Internal Network Bus 6 FRONT1 FDDI Front Panel Port 1 7 FRONT2 FDDI Front Panel Port 2 8 F...

Page 4: ...6 03 Module Specific Information 2 Use the numbers listed in Table 1 to configure the module s default interface see General Configuration Screen in the SmartSwitch 9000 Module Local Management User s Guide ...

Page 5: ...FDDI rings connected to the module Figure 1 Ring Map Configuration Screen SmartSwitch 9000 Local Management Ring Map Configuration Module Name 9F426 03 Firmware Revision 01 04 10 Slot Number 11 BOOTPROM Revision 01 02 00 FDDI Address 00 00 B8 00 10 62 MAC Count 1 Current RingMap FRONT PANEL 1 isolated Address Mode MAC 00 00 B8 00 10 62 NAS SMT Unknown Address FRONT PANEL 1 isolated EXIT RETURN ...

Page 6: ...entifies the ring on which a MAC for the specified module resides and whether that MAC is located on the primary or secondary path of that ring Address Mode Toggle Allows you to select the format in which addresses appear on this screen Press the Space Bar to toggle to the desired value The Address Mode possibilities are MAC Canonical FRONT PANEL x Toggle Allows you to display information about th...

Page 7: ...ects directly to an FDDI primary and secondary ring using A and B ports SAS Single Attached Station Station that accesses the main ring through a concentrator creating a ring of trees topology SAC Single Attached Concentrator Station that accesses the main ring through another concentrator and in turn allows the connection of more devices SACs provide the same connections as DACs without attaching...

Page 8: ...Screen SmartSwitch 9000 Local Management Ring Map Node Module Name 9F426 03 Firmware Revision 01 04 10 Slot Number 11 BOOTPROM Revision 01 02 00 SELECTED NODE Address 00 00 B8 00 10 62 Upstream Address NO UPSTREAM ADDRESS Node Class NAS Mac Count 0 Non Master Count 0 Master Count 0 Peer Wrap No Unattached Conc No Twisted A A No Twisted B B No Synchronous Service No Rooted No EXIT RETURN ...

Page 9: ...e selected node Master Count Displays the number of M ports controlled by the selected node Peer Wrap Indicates whether a wrap condition exists on a port A peer wrap does not occur when the A or B port is attached to an M port Unattached Conc DAC only Indicates whether the selected node has no active A or B port Twisted A A Indicates whether the A port is connected to another A port Twisted B B In...

Page 10: ...ration Module Name 9F426 03 Firmware Revision 01 04 10 Slot Number 9 BOOTPROM Revision 01 02 00 Switch Address 00 00 1D 00 08 45 Type of STA NONE Numbers of Ports 4 Port MAC Address State Status 1 00 00 1D 00 08 45 disabled DISABLED 2 00 00 1D 00 08 46 forwarding ENABLED 3 00 00 1D 00 08 47 forwarding ENABLED 4 00 00 1D 00 08 48 forwarding ENABLED SAVE EXIT RETURN Port refers to the following Port...

Page 11: ...interface No traffic can be received or forwarded while the interface is disabled Learning The bridge is learning this interface s network addresses The bridge enters the learning state when the Transparent Database is created during start up or after being deleted or when the Spanning Tree Algorithm detects a network topology change Listening The bridge is not adding information to the Transparen...

Page 12: ...ule s front panel ports Figure 4 Full Duplex Configuration Screen SmartSwitch 9000 Local Management Full Duplex Configuration Module Name 9F426 03 Firmware Revision 01 04 10 Slot Number 9 BOOTPROM Revision 01 02 00 PORT OPERATION MODE LINK STATUS PORT STATUS 1 FULL DUPLEX No Link ENABLED 2 FULL DUPLEX No Link ENABLED 3 FULL DUPLEX No Link ENABLED SAVE SET ALL PORTS FULL EXIT RETURN ...

Page 13: ...e same time Therefore the port is running at 100 Mbps LINK STATUS Indicates whether there is a physical connection from this port to another device One of the following values appears Link There is a link signal present there is a valid physical connection from this port to another device No Link There is no link signal present there is no valid physical connection from this port to another device...

Page 14: ...9F426 03 Module Specific Information 12 ...

Reviews: