USER’S GUIDE
188 CyberSWITCH
9.
Enter the authentication information needed. To begin entering the information, select
Authentication from the Device Table Menu. The following menu will then be displayed:
Provide the necessary device authentication information for your selected Line Protocol. (Refer
to
On-node Device Database Security Requirements
for details). For example, for a PPP device,
specify a CHAP secret. Or, for an HDLC device, enter a Bridge Ethernet Address.
For PPP, the ability to enable/disable outbound authentication (selection 3) is available.
However, it is generally not necessary to enable outbound authentications on a point-to-point
line. If the device is associated with a frame relay virtual circuit, and the PVC name is different
than the device name, then outbound authentication is required.
In addition, if you want to add user-level security to IP, AppleTalk and bridge devices, you
may also enable User Level Authentication. This requires the user that initiates a connection
between the remote device and the CyberSWITCH to be authenticated at the user level as well.
Refer to
Device and User Level Security
for details.
Note: Do not enable User Level Authentication for terminal server devices which connect
through the digital modem.
10. To enter any needed IP information for your device, select IP from the Device Table Menu. The
following screen will be displayed:
Device Authentication Menu: (device = "DAN")
PPP:
1) PAP Password ""
2) CHAP Secret ""
3) Outbound Authentication ENABLED
4) User Level Authentication DISABLED
IP Host (RFC 1294):
5) IP Host Id ""
HDLC Bridge:
6) Bridge Ethernet Address ""
7) Bridge Password ""
ISDN:
8) Calling Line Id(s) ""
Select function from above or <RET> for previous menu:
Device IP Menu: (device = "DAN")
1) IP Address NONE
2) IP Routing ENABLED
3) Make calls for IP data ENABLED
4) IP Input Filter NONE
5) IP Output Filter NONE
Select function from above or <RET> for previous menu: