Chapter 7: AT Commands and Registers
7-32
CSMIM-T1 Hardware Installation Guide
\Q4 enables unidirectional XON/XOFF flow control. The modem
serial port generates, but does not respond to, XON/XOFF flow
control characters. This setting allows for computers to transmit
data that has XON and XOFF data characters. The computer can
still be set to respond to XON/XOFF flow control characters sent
to it from the modem during serial-port flow control.
\Q5 enables unidirectional hardware flow control the same as
\Q2, but also keeps CTS Off until a connection is established.
\Q6 enables bi-directional hardware flow control the same as \Q3,
but also keeps CTS Off until a connection is established and
ignores RTS while not connected.
%R
n
Read All Registers
%R0
Displays the contents of all S registers in decimal and
hexadecimal integers in tabular format.
%R1
Displays the contents of all :T registers in decimal and
hexadecimal integers in tabular format.
&R
n
RTS/CTS Options
&R2
ITU-T V.13 emulates half-duplex over a full duplex line.
Use &R2 to simulate half-duplex operation.
S
n?
Read Configuration Registers
Where n is an integer from 0 to 27, indicating a register, displays
the contents in decimal form of the selected register.
&S
n
DSR Options
&S0
DSR always on.
&S1
DSR complies with ITU-T recommendations.
Controls the Data Set Ready (DSR) signal on the serial port.
NOTE
The modem ignores &R during asynchronous connections.
Summary of Contents for CSMIM-T1
Page 2: ......
Page 8: ...viii CSMIM T1 Hardware Installation Guide ...
Page 26: ...Chapter 1 INTRODUCTION 1 14 CSMIM T1 Hardware Installation Guide ...
Page 84: ...Chapter 4 CSMIM T1 Parameters 4 16 CSMIM T1 Hardware Installation Guide ...
Page 184: ...Chapter 7 AT Commands and Registers 7 58 CSMIM T1 Hardware Installation Guide ...
Page 188: ...Appendix A PORT PIN SIGNAL ALLOCATIONS A 4 CSMIM T1 Hardware Installation Guide ...