Installation
CTP100T USER’S MANUAL
Page 3-3
5.
Attach the CTP100T adapter to the Velcro mount.
6.
Proceed to Section 3.2.2 to complete the CTP100T adapter
installation.
3.2.2
Connecting to the Network
If you have mounted the CTP100T adapter as described in Section
3.2.1, proceed to step 2 and note the Caution. Otherwise, proceed to
step 1.
1.
Select an installation site for the CTP100T adapter that is within 6
feet of a USA standard (NEMA) 3-prong outlet.
Caution:
Take care not to cut any network or telephone lines
during installation. Failure to do so may result in interruption of data
and/or telephone service.
2.
Refer to Figure 3-1. Connect the twisted pair cable
➊
to the
CTP100T adapter
➒
by inserting the RJ45 connector into the
RJ45 port
➋
on the side of the CTP100T adapter.
3.
Attach the thin-net coaxial segment
➏
to the BNC port
➐
of the
CTP100T adapter. Set the Internal Termination switch
➑
to the up
( ) position to terminate the adapter internally, or the down ( )
position to terminate the segment externally. Use a T-connector
(not shown) when terminating the adapter externally. Ensure that
the segment is terminated at both ends.