Installation Checkout
CTP100T USER’S MANUAL
Page 4-3
4.
If you have not already attached a thin-net segment
➏
to the BNC
port of the CTP100T adapter
➎
, do so at this point. Use a
T-connector and 50-ohm terminator to terminate the segment if
you have set the termination switch in the down position ( ) for
external termination.
5.
Using an AUI cable
➑
, connect another LAN-MD
➒
to any
transceiver
➐
connected to the thin-net coaxial segment
➏
off of
the CTP100T adapter
➎
.
6.
On the LAN-MD
➊
connected in Step 1, select 6 - SERVER. This
LAN-MD will now act as the SERVER unit. It will also act as a
packet echoer when it is used with another LAN-MD.
Press the Start Test button. The test passes when the status
display on the LAN-MD reads 000, and the LAN-MD pass LED
comes on.
7.
On the LAN-MD
➒
that was connected in step 5, select 4 - NODE
and press the Start Test button. Check that this test passes.
At least 100 packets should be sent and received with no errors.
The packets will be received and sent back from the SERVER
LAN-MD
➊
that was left running on the other end of the segment.
When the CTP100T adapter has successfully completed this test,
the unit is ready for normal operation. If any failures were noted,
please contact Cabletron Systems Technical Support.