Management Terminal Setup
DLEHF-MA User’s Guide
5-5
5.3.3
Telnet Connections
Once the module or chassis has a valid IP address, the user can establish a
Telnet session with Local Management from any TCP/IP based station on
the network. Telnet connections to the DLEHF-MA require the passwords
assigned at the SNMP Community Names screen of either the
DLM6C-AA chassis or the module. For additional information about
these passwords, refer to Section 5.8. Refer to the instructions included
with the Telnet application for information about establishing a Telnet
session.
5.3.4
Connecting an Uninterruptible Power Supply
If the DLEHF-MA is connected to an American Power Conversion (APC)
Uninterruptible Power Supply (UPS) device for power, a connection from
its COM port to the UPS allows monitoring of the UPS power status. The
COM port must first be reconfigured to support the UPS connection using
the General Configuration LM screen as described in Section 5.15.11.
Refer to the UPS documentation for details on how to access the status
information.
Use the Console Cable Kit provided with the DLM6C-AA chassis to
attach the UPS to the module COM port as shown in Figure 5-2.
Connect the UPS device to the COM port of the DLEHF-MA as follows:
1.
Connect the RJ45 connector at one end of the cable to the COM port on
the DLEHF-MA.
2.
Plug the RJ45 connector at the other end of the cable into the
RJ45-to-DB9 male (UPS) adapter, Cabletron Systems Part No. 9372066.