Figure 2    Auxiliary Console Cabling - Console Port to Async Terminal

Figure 3    Auxiliary Console Cable - Console Port to Modem

Installation & Setup Guide

3

Installing an FRX4000

The customer and sales representative decide on the necessary hardware and 
software components at the time a FRX4000 is ordered. These components 
(except cables) are then installed before the unit is shipped to the customer. 
Steps to be taken at the customer site are described in this section.

1. Unpack and inspect the equipment. A shipment will generally include two 

boxes, the contents of which are described below. If there is evidence of 
physical damage, contact the transport company that delivered the 
equipment. If parts are missing, contact your sales representative.

Box 1 contains:

"Read Me First" packet: includes software license agreement, updates 
to this document, and other pertinent information.

FRX4000 (including serial expansion card, if ordered).

Power cable.

One V.35 DTE I/O cable.

Auxiliary Console cable set:
Cable FRX-PC-CAB
Cable FRX-MOD-CAB
Adapter FRX-9/25-ADAP.

Rack-mount kit:
 2

rack-mount brackets|

12 6-32x1/4 flat-head screws
 4

10-32x5/8 pan-head screws

 4

#10 split-ring lock washers

 4

#10 flat washers.

This Installation & Setup guide.

Box 2 contains all other cables that were ordered with the FRX4000.

2. Record the serial number found on the bottom of the FRX4000. This will 

be needed for any correspondence with Cabletron Systems concerning the 
device.

3. If you are not rack mounting the unit, go to step 5. If you are mounting the 

unit into a 19-inch rack, attach the mounting brackets as shown in Figure 
4, using the 6-32x¼ screws included with the brackets.

Note that the design of the brackets allows you to attach them with the tabs 
at either the front or the rear of the FRX4000.

4

FRX4000

Async terminal

FRX4000

PC-to-Console port cable
(FRX-PC-CAB)

Adapter
(FRX-9/25-ADAP)

Async terminal

FRX4000

Auxiliary Console cable
(FRX-MOD-CAB)

RS-232 cable

Auto-answer
modems

Summary of Contents for Netlink FRX4000

Page 1: ...Installation Setup Guide The Complete Networking Solution TM...

Page 2: ...measures to eliminate the interference To ensure compliance with the Class A FCC limits use only shielded cables with this equipment Any cable installed above a ceiling or below a floor must be of a...

Page 3: ...DSU interface is RJ 48S The cable must be provided by the customer Assuming that you ordered the necessary WAN interface cables with the FRX4000 you will need to know which cable will plug into which...

Page 4: ...RX4000 including serial expansion card if ordered Power cable One V 35 DTE I O cable Auxiliary Console cable set Cable FRX PC CAB Cable FRX MOD CAB Adapter FRX 9 25 ADAP Rack mount kit 2 rack mount br...

Page 5: ...in Figure 5 Figure 5 Mounting Angle Hole Spacing Installation Setup Guide 5 Figure 6 Rack Mounting the FRX4000 5 Plug all cables into the appropriate connectors at the rear of the unit see Figure 7 I...

Page 6: ...cure it to another cable or device The mating connector should have threaded 4 40 stand offs to accept the screws If it does not wrap the connection with cable ties electrical tape or something else t...

Page 7: ...Press C at the On Line Node Operations menu or B A C from the Main Menu 3 When prompted enter the File Transfer ID and password of the node you are updating 4 Press Y or N when asked Will the remote n...

Page 8: ...ions or problems please contact Cabletron Systems Technical Support at Phone 603 332 9400 Fax 603 337 3075 E mail support ctron com Installation Setup Guide 9 Document number 09 41 06 103 02 The Compl...

Reviews: