SEHI100TX User’s Guide
B-1
APPENDIX B
IMAGE FILE DOWNLOAD USING OID STRINGS
This appendix provides instructions for setting up a TFTP server and to
download an image file to the SEHI by setting specific MIB OID strings.
Set the OID strings with the SNMP Tools screen described in Chapter 7.
The SEHI supports the Standard Local Download application. In this
application the SEHI automatically disables management while download
of the new firmware image is in progress.
Before downloading the image to a device, you must do the following:
•
Load the image file onto your network TFTP server.
•
Decompress the image file.
NOTE
Download an image file to the SEHI with a remote
management package such as SPECTRUM, SPECTRUM
Element Manager, or the appropriate SPECTRUM Portable
Management Application. Refer to the specific package
documentation for image file download procedures.
NOTE
For information on how to set up a workstation as a TFTP
server, refer to your specific workstation documentation and
the guidelines outlined in this instruction guide.